Increasing the sensitivity of stellar intensity interferometry with optical telescopes: First laboratory test of spectral multiplexing

S Tolila,G Labeyrie,R Kaiser,J.-P Rivet,W Guerin
2024-11-13
Abstract:We present a preliminary laboratory test of a setup designed to measure Hanbury Brown and Twiss-type intensity correlations from a chaotic light source using five spectral channels simultaneously. After averaging the zero-delay correlation peaks from all channels, we obtain an improvement of the signalto-noise ratio fairly consistent with theory. The goal is to demonstrate the feasibility and scalability of this technique to improve the sensitivity of stellar intensity interferometry using optical telescopes.
Instrumentation and Methods for Astrophysics
What problem does this paper attempt to address?
The problem that this paper attempts to solve is to improve the sensitivity of Stellar Intensity Interferometry (SII). Specifically, the author improves the signal - to - noise ratio (SNR) of SII through multi - channel spectral multiplexing technology, thereby enhancing the observation effect. ### Background and Problem Compared with Stellar Amplitude Interferometry (SAI), the traditional Stellar Intensity Interferometry (SII) has lower sensitivity, which limits its application range, especially for the observation of fainter stars. The main advantage of SII is that it is insensitive to the phase of light, so it is relatively easy to implement, but its low sensitivity makes it only applicable to the observation of very bright stars. In recent years, with the progress of detectors, digital electronics technology and photonics technology, SII technology has experienced a renaissance. ### Solution To solve the problem of low sensitivity of SII, the author proposes a new method: **spectral multiplexing**. Specifically, they designed an experimental device that can perform intensity - correlation measurements simultaneously on multiple wavelength channels. Through this method, the signal - to - noise ratio can be significantly improved while maintaining high contrast. ### Experimental Design The author conducted a preliminary laboratory test, using 5 spectral channels to perform intensity - correlation measurements. The experimental device includes: - Using a halogen lamp to simulate the stellar light source - Dispersing light into different wavelength channels through a transmission grating - Using multimode fiber and avalanche photodiode (APD) for detection - Calculating and storing the time - intensity - correlation signal of each channel ### Experimental Results The experimental results show that by averaging the correlation peaks from all channels, the signal - to - noise ratio has been significantly improved. Specifically, the signal - to - noise ratios of individual channels are 32, 22, 30, 21 and 25 respectively, while the averaged signal - to - noise ratio reaches 51, slightly lower than the theoretical expected value of 59. In addition, the correlation peaks of different channels have different contrasts and widths, which may be due to the different time responses of the detectors in each channel. ### Conclusion and Outlook The author has verified the effectiveness of multi - channel spectral multiplexing technology through this preliminary experiment and demonstrated its potential in improving the sensitivity of SII. However, some limitations and problems requiring further research have also been found in the experiment, such as the difference in coupling efficiency between different channels. Future work will be dedicated to expanding to more channels and using advanced photonics devices such as single - photon avalanche diode arrays (SPAD) and photon lanterns to achieve a more compact and stable device. ### Formula Summary The expression for the signal - to - noise ratio (SNR) is: \[ \text{SNR} = \alpha V^2 \frac{N_{\text{ph}}(\lambda) A r}{4 \pi \tau_{\text{el}}} \] where: - \( \alpha \) is the total photon detection efficiency - \( V^2 \) is the square of the visibility - \( N_{\text{ph}}(\lambda) \) is the incident spectral photon flux - \( A \) is the light - collecting area - \( T_{\text{obs}} \) is the observation time - \( \tau_{\text{el}} \) is the electronic time resolution of detection Through spectral multiplexing, SNR is expected to increase as \( \sqrt{N} \) with the increase of the number of channels \( N \).