Kazunori Asakura,Kiyoshi Hayashida,Tomokage Yoneyama,Hirofumi Noda,Marina Yoshimoto,Tomohiro Hakamata,Hironori Matsumoto,Hiroshi Tsunemi
Abstract:We have been developing an x-ray imaging system, Multi-Image X-ray Interferometer Module (MIXIM), to achieve a high angular resolution with a compact system size. MIXIM is comprised of a mask with equally-spaced apertures and an x-ray detector. The aperture size and mask-detector distance determine the system's angular resolution. Although a smaller aperture gives a better resolution, the degree of improvement is limited by a diffraction effect. MIXIM circumvents this problem by utilizing the Talbot effect. Our experiment with the previous model equipped with a multi-pinhole mask obtained an angular resolution of 0.5" with a mask-detector distance of 92 cm. A major downside of the multi-pinhole mask is, however, that it has a very low opening fraction, which results in a very low effective area. Here, we newly adopt to MIXIM a multiple coded aperture (MCA) mask, an array of coded aperture patterns. Our proof-of-concept experiment demonstrates that the Talbot effect works even for the MCA mask with a high opening fraction of ~50% at 12.4 keV. Consequently, the new MIXIM realizes about 25 times as large an effective area as that of the previous model, while maintaining a high angular resolution of 0.2" and a compact size of ~1.5 m.
What problem does this paper attempt to address?
The problem that this paper attempts to solve is to develop a compact X - ray imaging system that can significantly increase the effective area while maintaining high angular resolution. Specifically, the authors propose a new method to overcome the problem of low effective area in traditional systems by using a multi - aperture - coded - aperture (MCA) mask instead of the traditional multi - pinhole mask.
### Problem Background
1. **Requirement for High Angular Resolution**:
- In X - ray astronomy, high angular resolution is crucial for analyzing the spatial structure of celestial X - ray sources and diagnosing their physical properties.
- The current state - of - the - art X - ray telescopes such as Chandra, although having an extremely high angular resolution (0.5 arc - seconds), face limitations in further improving the resolution due to manufacturing precision.
2. **Limitations of Existing Systems**:
- Existing high - resolution X - ray imaging systems (such as Wolter I - type telescopes) are limited by manufacturing technology and it is difficult to further improve the resolution.
- X - ray interferometers (such as MAXIM), although theoretically capable of achieving higher resolution, require very large system sizes (such as a mirror - detector distance of 200 kilometers) and there are many technical challenges in practical applications.
3. **Development of Multi - Image X - ray Interferometer Module (MIXIM)**:
- MIXIM is a system based on equally - spaced apertures and X - ray detectors, which utilizes the Talbot effect to achieve high angular resolution.
- Initial experiments show that MIXIM can achieve an angular resolution of 0.5 arc - seconds at a distance of 92 centimeters, but under the multi - pinhole mask, due to the extremely low aperture ratio (only 1.3%), the effective area is very small and cannot meet the actual observation requirements.
### Solution
In order to increase the effective area of MIXIM without sacrificing high angular resolution, the authors introduce the multi - aperture - coded - aperture (MCA) mask. The MCA mask has the following advantages:
- **High Aperture Ratio**: The aperture ratio of the MCA mask can reach about 50%, which is more than 20 times higher than that of the multi - pinhole mask.
- **Maintaining High Angular Resolution**: By precisely controlling the distance between the mask and the detector and using the Talbot effect, the MCA mask can still achieve high angular resolution.
- **Compactness**: While maintaining high angular resolution, the overall size of the new system is still about 1.5 meters, which is suitable for being carried by a single satellite.
### Experimental Verification
The authors carried out a proof - of - concept experiment, using three MCA masks with different designs (patterns A, B, C), and tested them in the SPring - 8 synchrotron radiation facility. The experimental results show that:
- The MCA mask can form self - images, verifying the effectiveness of the Talbot effect in complex aperture patterns.
- The new system achieves a high angular resolution of about 0.2 arc - seconds, and at the same time, the effective area is increased by about 25 times compared to the previous model.
- The separation experiment of two point sources shows that the MCA mask can accurately distinguish two point sources that are 0.540 arc - seconds apart, verifying its high angular resolution.
### Conclusion
By using the multi - aperture - coded - aperture mask, MIXIM has successfully solved the problem of low effective area while maintaining high angular resolution and a compact system size. This innovation provides new possibilities for future high - resolution X - ray astronomical observations.
---
In summary, this paper aims to solve the problems of low effective area and difficulty in improving angular resolution in existing X - ray imaging systems by introducing the multi - aperture - coded - aperture mask, thereby providing a feasible and efficient new method for high - resolution X - ray astronomical observations.