Near-Field Coupling Coil System: A Novel Radiofrequency Coil Solution for MRI

Zhiguang Mo,Shao Che,Enhua Xiao,Qiaoyan Chen,Feng Du,Nan Li,Sen Jia,Changjun Tie,Bing Wu,Xiaoliang Zhang,Hairong Zheng,Ye Li
2024-09-30
Abstract:The performance of radiofrequency (RF) coils has a significant impact on the quality and speed of magnetic resonance imaging (MRI). Consequently, rigid coils with attached cables are commonly employed to achieve optimal SNR performance and parallel imaging capability. However, since the adoption of MRI in clinical imaging, both patients and doctors have long suffered from the poor examination experience and physical strain caused by the bulky housings and cumbersome cables of traditional coils. This paper presents a new architectural concept, the Near-Field Coupling (NFC) coil system, which integrates a pickup coil array within the magnet with an NFC coil worn by the patient. In contrast to conventional coils, the NFC coil system obviates the necessity for bed-mounted connectors. It provides a lightweight, cost-effective solution that enhances patient comfort and supports disposable, custom designs for the NFC coils. The paper also derives the SNR expression for the NFC coil system, proposes two key design principles, and demonstrates the system's potential in SNR and parallel imaging through an implementation case.
Medical Physics
What problem does this paper attempt to address?
The paper aims to address the issues associated with radiofrequency (RF) coils in magnetic resonance imaging (MRI), specifically focusing on the following aspects: 1. **The bulkiness and inconvenience of traditional coils**: - Traditional RF coils are bulky and come with complex cable connections, leading to a poor experience for patients during examinations and inconvenience for doctors during operations. - These cables not only add to the physical burden on patients but also pose safety risks such as burns. 2. **Signal-to-noise ratio (SNR) and parallel imaging capability**: - The design of traditional coils usually focuses on improving SNR, but as coil density increases, the number of cables also increases, making the system more complex and difficult to manage. - The parallel imaging capability is limited by the insufficient number of coil channels, which is particularly evident when using body coils or spine coils. To address the above issues, the paper proposes a new near-field coupling (NFC) coil system design with the following main features: - **Wireless design**: By integrating the receive coil array into the magnet and having the patient wear the NFC coil, the need for traditional bed-mounted connectors is eliminated. - **Lightweight and low cost**: The NFC coil system has a simple structure, requiring no additional RF components, making it lighter and more cost-effective, while also supporting customizable and disposable designs. - **Improved SNR and parallel imaging performance**: The paper derives the SNR expression for the NFC coil system and proposes two key design principles, verifying its potential in enhancing SNR and parallel imaging performance. - **Flexibility**: The NFC coil can be customized according to different anatomical regions to achieve optimal SNR results. In summary, this research aims to overcome the limitations of existing technology by introducing the NFC coil system, providing a more efficient, comfortable, and economical MRI solution.