The i-TED Compton Camera Array for real-time boron imaging and determination during treatments in Boron Neutron Capture Therapy

Pablo Torres-Sánchez,Jorge Lerendegui-Marco,Javier Balibrea-Correa,Victor Babiano-Suárez,Bernardo Gameiro,Ion Ladarescu,Patricia Álvarez-Rodríguez,Jean-Michel Daugas,Ulli Koester,Caterina Michelagnoli,Maria Pedrosa-Rivera,Ignacio Porras,Maria José Ruiz-Magaña,Carmen Ruiz-Ruiz,César Domingo-Pardo
2024-09-16
Abstract:This paper explores the adaptation and application of i-TED Compton imagers for real-time dosimetry in Boron Neutron Capture Therapy (BNCT). The i-TED array, previously utilized in nuclear astrophysics experiments at CERN, is being optimized for detecting and imaging 478 keV gamma-rays, critical for accurate BNCT dosimetry. Detailed Monte Carlo simulations were used to optimize the i-TED detector configuration and enhance its performance in the challenging radiation environment typical of BNCT. Additionally, advanced 3D image reconstruction algorithms, including a combination of back-projection and List-Mode Maximum Likelihood Expectation Maximization (LM-MLEM), are implemented and validated through simulations. Preliminary experimental tests at the Institut Laue-Langevin (ILL) demonstrate the potential of i-TED in a clinical setting, with ongoing experiments focusing on improving imaging capabilities in realistic BNCT conditions.
Medical Physics
What problem does this paper attempt to address?
The problem that this paper attempts to solve is to achieve real - time dosimetry during Boron Neutron Capture Therapy (BNCT). Specifically, the current standard method estimates boron distribution by measuring the boron concentration in the patient's blood and combining it with the 18F - FBPA positron emission tomography (PET) performed before treatment. However, this method has serious limitations because it requires extrapolation from the data of the labeled compound on different dates and assumes that the blood has the same pharmacokinetic characteristics as the tumor and target organs. Therefore, directly measuring the boron concentration during treatment remains one of the main challenges faced by BNCT. In addition, determining only the boron concentration is not sufficient for BNCT dosimetry; it also needs to be multiplied by the neutron flux at each point, which increases the overall uncertainty. However, the neutron capture reaction of boron can be marked by the emission of 478 keV gamma rays, and these gamma rays can be used to monitor the product of the boron concentration and the neutron flux, thereby achieving an accurate assessment of the boron dose, which is the main component of the dose in BNCT treatment. At the same time, this quantity is also proportional to the thermal neutron dose because the 14N(n,p) reaction (the main component of the thermal dose) and the 2224 keV gamma rays produced by the neutron capture of hydrogen behave similarly. Therefore, if these 2224 keV gamma rays can be imaged, the thermal neutron dose can also be better estimated. To overcome the limitations of existing technologies, the paper explores the application of the i - TED Compton camera array, aiming to optimize its ability to detect and image 478 keV gamma rays to adapt to the high - radiation environment in BNCT treatment. By optimizing the i - TED detector configuration through detailed Monte Carlo simulations and implementing and validating advanced 3D image reconstruction algorithms (such as the back - projection and list - mode maximum likelihood expectation - maximization (LM - MLEM) algorithms), the paper demonstrates the potential of i - TED in a clinical environment. Preliminary experimental tests further prove the application prospects of i - TED in BNCT treatment.