Performance of the Southern Astrophysical Research Telescope Speckle Instrument

Andrei Tokovinin
2024-08-22
Abstract:The High Resolution Camera (HRCam) speckle imager at the 4.1 m Southern Astrophysical Research telescope is a highly productive instrument that has accumulated about 40K observations to date. Its performance (detected flux, level of the speckle signal, signal-to-noise ratio, and limiting magnitude) is studied here using both the actual data and realistic simulations, including the detector noise. In the calculation of the speckle power spectrum, signal clipping is essential to reduce the noise impact and maximize the sensitivity. Increasing exposure time of individual frames beyond 30 ms does not improve the limiting magnitude, which ranges from 11.5 to 14 mag under a seeing from 1.6" to 0.6" in the wide-band I filter. A gain of at least one magnitude is expected if the current electron multiplication CCD is replaced by a high-end CMOS detector with a sub-electron readout noise. This study will help in planning, executing, and automating future speckle observations with HRCam and other speckle imagers.
Instrumentation and Methods for Astrophysics
What problem does this paper attempt to address?
The main problem that this paper attempts to solve is to evaluate and quantify the performance of the High - Resolution Camera (HRCam) of the SOAR telescope, especially its performance under different observation conditions. Specifically, the research focuses on the following: 1. **Detection Flux, Speckle Signal Level, Signal - to - Noise Ratio, and Limiting Magnitude**: These parameters are the key indicators for measuring the performance of HRCam. 2. **The Influence of Exposure Time and Spectral Bandwidth**: Study the influence of limited exposure time and wide spectral bandwidth on the speckle signal in order to optimize the data acquisition strategy. 3. **The Influence of Detector Noise**: Evaluate the performance differences between Electron - Multiplying CCD (EM CCD) and low - noise CMOS detectors through simulation experiments, and explore the potential gain of upgrading detectors. ### Main Objectives - **Quantify the Quality of Speckle Data**: Quantify the performance of HRCam through parameters such as speckle contrast and signal - to - noise ratio (SNR), and study how these parameters depend on observation conditions and instrument parameters. - **Plan Future Observations**: Based on performance evaluation, set acceptable conditions for future observations to improve observation efficiency. - **Automate Observations**: The ultimate goal is to automate observations and reduce the dependence on observers' experience. - **Evaluate the Upgrade Potential**: Evaluate the possible sensitivity improvement brought by replacing the existing EM CCD with a high - end CMOS detector. ### Key Formulas - **Instrument Magnitude Calculation Formula**: \[ m_{\text{inst}} = 25- 2.5\log_{10}\left(\frac{gF}{tE_g}\right) \] where \(g\) is the conversion factor (10.1 e - /ADU), \(F\) is the flux measured per frame (ADU), \(t\) is the exposure time (seconds), and \(E_g\) is the EM gain. - **Binary Star Parameter Fitting Model**: \[ P(f)\approx P_0(f)[1 - B + B\cos(2\pi f x)] \] \[ B=\frac{2r}{1 + r^2} \] \[ r = 10^{-0.4\Delta m} \] where \(f\) and \(x\) are the two - dimensional vectors of spatial frequency and binary star position respectively, \(B\) is the fringe contrast in PS, \(r\) is the intensity ratio of the two stars, and \(\Delta m\) is the magnitude difference. Through the research of these problems, the author hopes to provide theoretical support and technical guidance for future speckle interferometry, especially in the field of high - resolution astronomical observations.