Speckle Interferometry with CMOS Detector

I. A. Strakhov,B. S. Safonov,D. V. Cheryasov
DOI: https://doi.org/10.1134/S1990341323020104
2023-04-30
Abstract:In 2022 we carried out an upgrade of the speckle polarimeter (SPP) -- the facility instrument of the 2.5-m telescope of the Caucasian Observatory of the SAI MSU. During the overhaul, CMOS Hamamatsu ORCA-Quest qCMOS C15550-20UP was installed as the main detector, some drawback of the previous version of the instrument were eliminated. In this paper, we present a description of the instrument, as well as study some features of the CMOS detector and ways to take them into account in speckle interferometric processing. Quantitative comparison of CMOS and EMCCD in the context of speckle interferometry is performed using numerical simulation of the detection process. Speckle interferometric observations of 25 young variable stars are given as an example of astronomical result. It was found that BM And is a binary system with a separation of 273 mas. The variability of the system is dominated by the brightness variations of the main component. A binary system was also found in NSV 16694 (TYC 120-876-1). The separation of this system is 202 mas.
Instrumentation and Methods for Astrophysics
What problem does this paper attempt to address?
The paper primarily explores the use of Complementary Metal-Oxide-Semiconductor (CMOS) detectors for speckle interferometry in the field of astronomy and addresses some issues present in previous equipment. Specifically: 1. **Equipment Upgrade**: The research team upgraded the speckle polarimeter on the 2.5-meter telescope at the Caucasus Observatory of Moscow State University. They replaced the previous Electron Multiplying Charge-Coupled Device (EMCCD) with a new CMOS detector (Hamamatsu ORCA-Quest qCMOS C15550-20UP). This improvement aims to enhance the performance of the equipment and resolve the shortcomings of the older version. 2. **CMOS vs. EMCCD Comparison**: Through numerical simulation methods, a quantitative comparison was made between CMOS and EMCCD in speckle interferometry. The experimental results indicate that the newly installed CMOS detector has significant advantages in terms of readout noise and quantum efficiency, especially under low photon flux conditions. 3. **Astronomical Observation Examples**: The paper presents the results of speckle interferometry observations of 25 young variable stars using the upgraded equipment. It was found that BM And is a binary system with a separation angle of 273 milliarcseconds; NSV 16694 (TYC 120-876-1) is also a binary system with a separation angle of 202 milliarcseconds. In summary, the paper aims to improve high-resolution imaging capabilities in astronomical observations, particularly in the field of speckle interferometry, by introducing advanced CMOS detection technology and demonstrates significant results in practical applications.