The XOC X-ray Beamline: Probing Colder, Quieter, and Softer

Haley R. Stueber,Tanmoy Chattopadhyay,Sven C. Herrmann,Peter Orel,Tsion Gebre,Aanand Joshi,Steven W. Allen,Glenn Morris,Artem Poliszczuk
2024-07-24
Abstract:Future strategic X-ray satellite telescopes, such as the probe-class Advanced X-ray Imaging Satellite (AXIS), will require excellent soft energy response in their imaging detectors to enable maximum discovery potential. In order to characterize Charge-Coupled Device (CCD) and Single Electron Sensitive Read Output (SiSeRO) detectors in the soft X-ray region, the X-ray Astronomy and Observational Cosmology (XOC) group at Stanford has developed, assembled, and commissioned a 2.5-meter-long X-ray beamline test system. The beamline is designed to efficiently produce monoenergetic X-ray fluorescence lines in the 0.3-10 keV energy range and achieve detector temperatures as low as 173 K. We present design and simulation details of the beamline, and discuss the vacuum, cooling, and X-ray fluorescence performance achieved. As a workhorse for future detector characterization at Stanford, the XOC beamline will support detector development for a broad range of X-ray astronomy instruments.
Instrumentation and Methods for Astrophysics,High Energy Astrophysical Phenomena,Instrumentation and Detectors
What problem does this paper attempt to address?
The problems that this paper attempts to solve are: in order to support the next - generation X - ray astronomical observation missions (such as AXIS), develop and verify an efficient, low - temperature X - ray beamline test system to characterize and optimize charge - coupled devices (CCDs) and single - electron - sensitive readout (SiSeRO) detectors for the soft X - ray region. Specifically, the research aims to: 1. **Improve soft X - ray response performance**: Ensure that the imaging detector has excellent soft - energy response in the 0.3 - 10 keV energy range to maximize the discovery potential. 2. **Achieve low - temperature operation**: Enable the detector to work at a temperature as low as 173 K, thereby reducing noise and increasing sensitivity. 3. **Provide accurate X - ray fluorescence lines**: Generate mono - energetic X - ray fluorescence lines by using a rotatable target wheel, cover the required energy range, and ensure high purity and low background radiation. 4. **Support future mission requirements**: Provide a reliable test platform for the development of future X - ray astronomical instruments, simulating the vacuum conditions and operating requirements in the actual space environment. ### Specific problem summary - **How to meet the requirements of future X - ray satellite telescopes?** - In particular, advanced X - ray imaging satellites such as AXIS require high - performance detectors to achieve higher spatial resolution and a wider field of view. - **How to overcome the limitations of existing technologies?** - Current HCDs and DEPFET detectors have deficiencies in noise and pixel size and cannot fully meet the requirements of high - resolution imaging. - **How to design and construct a test system capable of simulating the real - space environment?** - Including vacuum conditions, low - temperature cooling systems, and the selection of efficient X - ray sources and fluorescent target materials. By solving these problems, researchers hope to provide crucial technical support for the next - generation X - ray astronomical observations and ensure that the detectors can achieve the best performance in practical applications.