Ultra-low noise laser and optical frequency comb-based timing system for the Black Hole Explorer (BHEX) mission

Hannah Tomio,Guangning Yang,Holly F. Leopardi,Kenji Numata,Anthony W. Yu,Andrew Attar,Xiaozhen Xu,Wei Lu,Cheryl Gramling,T. K. Sridharan,Peter Kurczynski
2024-06-15
Abstract:In this effort, we demonstrate the performance of a highly stable time reference for the proposed Black Hole Explorer (BHEX) mission, a space-based extension to the Event Horizon Telescope (EHT) Very Long Baseline Interferometry (VLBI) project. This precision timing system is based on the use of a space-qualified, ultra-low noise laser developed as part of the Laser Interferometer Space Antenna (LISA) mission as the timing reference, and an optical frequency comb to transfer the stability of this laser to the microwave regime for instrumentation use. We describe the implementation of this system and experimental setup to characterize the stability performance. We present the results of this experiment that demonstrate the performance of this system meets requirements for the BHEX mission.
Instrumentation and Methods for Astrophysics
What problem does this paper attempt to address?
The problem that this paper attempts to solve is to provide a highly stable clock reference system for the proposed Black Hole Explorer (BHEX) mission. Specifically, the BHEX mission is a space - expansion project of the Event Horizon Telescope (EHT), aiming to improve the observational resolution and time resolution of black holes through the Very Long Baseline Interferometry (VLBI) technique. ### Main problems: 1. **Highly stable time reference**: In order to ensure the signal coherence among multiple space telescopes, a very stable time reference system is required. An unstable clock will lead to the impairment of phase coherence, thus limiting the integration time and degrading the performance of the VLBI system. 2. **Adaptability to the space environment**: Traditional hydrogen masers and other atomic clocks are difficult to be applied to space platforms due to limitations in size, weight, and power (SWaP). Therefore, it is necessary to develop a smaller, lighter, lower - power - consumption time reference system that can operate stably in space. ### Solutions: The paper proposes a technique based on an ultra - low - noise laser and an optical frequency comb to achieve this goal. The specific methods are as follows: - **Ultra - low - noise laser**: Use the space - qualified ultra - low - noise laser being developed in the LISA (Laser Interferometer Space Antenna) mission as a time reference. - **Optical frequency comb**: Utilize the optical frequency comb to transfer the stability of the laser to the microwave frequency band for use in instruments. The optical frequency comb can convert the optical frequency to the microwave frequency while maintaining extremely high frequency stability. ### Experimental verification: The researchers verified the performance of this system through experiments. The results show that it achieves a fractional frequency stability of \(1\times10^{- 14}\) to \(5\times10^{-14}\) within a 10 - second integration time, meeting the preliminary requirements of the BHEX mission. ### Future work: Future research will continue to improve the test setup and measurement methods to further enhance the performance of the system and seek to enable the optical frequency comb to operate reliably in the space environment. Through these efforts, the research team hopes to provide a high - performance, low - SWaP time reference system for future space VLBI missions, thereby promoting high - precision observations of celestial bodies such as black holes.