Detection of Low-Energy Electrons with Transition-Edge Sensors

Carlo Pepe,Benedetta Corcione,Francesco Pandolfi,Hobey Garrone,Eugenio Monticone,Ilaria Rago,Gianluca Cavoto,Alice Apponi,Alessandro Ruocco,Federico Malnati,Danilo Serazio,Mauro Rajteri
2024-07-17
Abstract:We present the first detection of electrons with kinetic energy in the 100 eV range with transition-edge sensors (TESs). This has been achieved with a $(100\times 100)$ $\mu$m$^2$ Ti-Au bilayer TES, with a critical temperature of about 84 mK. The electrons are produced directly in the cryostat by an innovative cold source based on field emission from vertically-aligned multiwall carbon nanotubes. We obtain a Gaussian energy resolution between 0.8 and 1.8 eV for fully-absorbed electrons in the $(90-101)$ eV energy range, which is found to be compatible with the resolution of this same device for photons in the same energy range. This work opens new possibilities for high-precision energy measurements of low-energy electrons.
Instrumentation and Detectors
What problem does this paper attempt to address?
The problem this paper attempts to address is: how to use Transition-Edge Sensors (TES) to accurately detect low-energy electrons (electrons with energy within the 100 eV range). Specifically, the researchers developed an innovative low-temperature electron source based on the field emission technology of vertically aligned multi-walled carbon nanotubes (CNTs) and successfully achieved this goal. ### Main Issues and Background 1. **Challenges in Low-Energy Electron Detection**: - Traditional detection methods such as Microchannel Plates (MCPs) and silicon detectors (such as avalanche photodiodes and silicon drift detectors) suffer from low geometric efficiency and poor energy resolution. - TES devices have shown excellent energy resolution in photon detection, but research on detecting low-energy electrons is relatively scarce. 2. **Limitations of Existing Research**: - Currently, research on using TES to detect low-energy electrons is very limited, and existing studies mainly focus on the 300-2000 eV energy range with relatively high energy resolution (σe > 17 eV). - Low-energy electrons are easily absorbed or scattered before entering the detector, leading to signal loss and decreased energy resolution. ### Research Objectives - **Develop a New Low-Temperature Electron Source**: Use vertically aligned multi-walled carbon nanotubes (CNTs) as the electron source to generate low-energy electrons at low temperatures through field emission technology. - **Optimize TES Design**: Design and manufacture TES devices suitable for detecting low-energy electrons, including adding shielding layers to reduce noise and improve detection efficiency. - **Achieve High-Precision Detection**: Validate through experiments to achieve high-precision detection of low-energy electrons within the 100 eV range, with energy resolution between 0.8 and 1.8 eV. ### Experimental Methods - **Electron Source**: Use vertically aligned multi-walled carbon nanotubes (CNTs) as the electron source to generate low-energy electrons at low temperatures through field emission technology. - **TES Device**: Use a Ti-Au bilayer TES with an area of (100 × 100) µm² and a critical temperature of approximately 84 mK. - **Experimental Setup**: Place the TES and CNTs on two separate copper plates, maintaining electrical insulation and thermal conduction through a 0.5 mm thick sapphire spacer. Control the emission energy of electrons by adjusting the voltage Vcnt. - **Data Acquisition**: Use a SQUID array to read the current signal generated by the TES and measure the electron current with a Keithley 6487 picoammeter. ### Main Results - **High Energy Resolution**: Achieved Gaussian energy resolution of 0.8 to 1.8 eV in the 90-101 eV energy range, comparable to the resolution of photon detection in the same energy range. - **Validation of Detection Mechanism**: The study shows that the thermal-based detection mechanism of TES for low-energy electrons is the same as for photons, providing confidence for further reducing electron energy in future experiments. - **Application Prospects**: This research is significant for β-decay and neutrino physics experiments, especially the PTOLEMY project, which plans to search for the cosmic neutrino background by analyzing the β-decay endpoint of tritium, aiming to achieve 50 meV energy resolution for 10 eV electrons. In summary, this paper successfully achieved high-precision detection of low-energy electrons within the 100 eV range through an innovative low-temperature electron source and optimized TES design, providing important technical support for future high-precision experiments.