First measurement of Gallium Arsenide as a low-temperature calorimeter

D. L. Helis,A. Melchiorre,A. Puiu,G. Benato,P. Carniti,A. Continenza,N. Di Marco,A. Ferella,C. Ferrari,F. Giannesi,C. Gotti,E. Monticone,L. Pagnanini,G. Pessina,S. Pirro,G. Profeta,M. Rajteri,P. Settembri,A. Shaikina,C.Tresca,D. Trotta
2024-04-24
Abstract:In this paper, we present the first measurement of a Gallium Arsenide crystal working as low-temperature calorimeter for direct Dark Matter (DM) searches within the DAREDEVIL (DARk-mattEr DEVIces for Low energy detection) project. In the quest for direct dark matter detection, innovative approaches to lower the detection thershold and explore the sub-GeV mass DM range, have gained high relevance in the last decade. This study presents the pioneering use of Gallium Arsenide (GaAs) as a low-temperature calorimeter for probing the dark matter-electron interaction channel. Our experimental setup features a GaAs crystal at ultralow temperature of 15 mK, coupled with a Neutron Transmutation Doped (NTD) thermal sensor for precise energy estimation. This configuration is the first step towards the detection of single electrons scattered by dark matter particles within the GaAs crystal, to significantly improve the sensitivity to low-mass dark matter candidates.
High Energy Physics - Experiment,Instrumentation and Detectors
What problem does this paper attempt to address?
This paper explores for the first time the application of gallium arsenide (GaAs) as a low-temperature thermal detector in direct dark matter searches. The research team used this crystal as a detector in the DAREDEVIL project, aiming to extend the sensitivity to low-mass dark matter candidates by detecting electron scattering. They designed an experimental setup to cool the GaAs crystal to 15 millikelvin and combined it with neutron transmutation doped (NTD) thermal sensors for precise energy measurements. The paper provides a detailed description of the detector's response characteristics, calibration spectra (using alpha particle and X-ray events), and performance evaluation. The experimental results show an energy resolution of approximately 546 electron volts and a baseline resolution slightly below 542 electron volts, setting a 3σ baseline noise threshold below 1.5 keV. Despite current limitations, such as non-low-radioactivity environments and high event rates due to high-activity sources, these results indicate the potential of GaAs crystals as low-temperature thermal detectors for detecting low-mass dark matter. Future work plans include introducing low-temperature light detectors for measuring fluorescence signals and installing electrodes for charge collection, aiming to detect individual electron-hole pairs. In addition, the research team considers using transition edge sensors (TES) to further improve the threshold and measurement capability, thus promoting the development of direct dark matter detection technology and exploring parameter space that has not yet been explored in the field of dark matter.