Direct Detection of MeV-Scale Dark Matter Utilizing Germanium Internal Amplification for the Charge Created by the Ionization of Impurities

D.-M. Mei,G.-J. Wang,H. Mei,G. Yang,J. Liu,M. Wagner,R. Panth,K. Kooi,Y.-Y. Li,W.-Z. Wei
DOI: https://doi.org/10.1140/epjc/s10052-018-5653-z
2017-08-22
Abstract:Light, MeV-scale dark matter (DM) is an exciting DM candidate that is undetectable by current experiments. A germanium (Ge) detector utilizing internal charge amplification for the charge carriers created by the ionization of impurities is a promising new technology with experimental sensitivity for detecting MeV-scale DM. We analyze the physics mechanisms of the signal formation, charge creation, charge internal amplification, and the projected sensitivity for directly detecting MeV-scale DM particles. We present a design for a novel Ge detector at helium temperature ($\sim$4 K) enabling ionization of impurities from DM impacts. With large localized E-fields, the ionized excitations can be accelerated to kinetic energies larger than the Ge bandgap at which point they can create additional electron-hole pairs, producing intrinsic amplification to achieve an ultra-low energy threshold of $\sim$0.1 eV for detecting low-mass DM particles in the MeV scale. Correspondingly, such a Ge detector with 1 kg-year exposure will have high sensitivity to a DM-nucleon cross section of $\sim$5$\times$10$^{-45}$ cm$^{2}$ at a DM mass of $\sim$10 MeV/c$^{2}$ and a DM-electron cross section of $\sim$5$\times$10$^{-46}$cm$^{2}$ at a DM mass of $\sim$1 MeV/c$^2$.
Instrumentation and Detectors,High Energy Physics - Experiment
What problem does this paper attempt to address?
The problem that this paper attempts to solve is: current experimental techniques are unable to directly detect light - mass dark matter (on the MeV scale). The paper proposes a new technique using the internal charge amplification mechanism in germanium (Ge) to achieve direct detection of MeV - scale dark matter. This new - type germanium detector can operate at an extremely low energy threshold (< 10 eV), thus being able to detect the charge carriers generated by the ionization of dark matter and impurity ions, and improve the detection sensitivity by internally amplifying these charge signals. Specifically, the paper analyzes physical mechanisms such as signal formation, charge generation, internal charge amplification, and the expected detection sensitivity. The research designs a germanium detector that operates at helium temperature (about 4 K) and can ionize impurities from dark matter collisions. By applying a large local electric field, the ionized excited states can be accelerated to an energy higher than the germanium bandgap, thereby generating additional electron - hole pairs to achieve internal amplification and reach an ultra - low energy threshold (about 0.1 eV) for detecting low - mass MeV - scale dark matter particles. In addition, the paper also evaluates the high sensitivity of this germanium detector at an exposure of 1 kg - year. That is, for a dark matter mass of about 10 MeV/c², its sensitivity to the dark matter - nucleon cross - section is about 5×10⁻⁴⁵ cm²; for a dark matter mass of about 1 MeV/c², its sensitivity to the dark matter - electron cross - section is about 5×10⁻⁴⁶ cm². This indicates that this new - type germanium detector has significant advantages in detecting MeV - scale dark matter.