HiRIS: an Airborne Sonar Sensor with a 1024 Channel Microphone Array for In-Air Acoustic Imaging

Dennis Laurijssen,Walter Daems,Jan Steckel
2024-02-21
Abstract:Airborne 3D imaging using ultrasound is a promising sensing modality for robotic applications in harsh environments. Over the last decade, several high-performance systems have been proposed in the literature. Most of these sensors use a reduced aperture microphone array, leading to artifacts in the resulting acoustic images. This paper presents a novel in-air ultrasound sensor that incorporates 1024 microphones, in a 32-by- 32 uniform rectangular array, in combination with a distributed embedded hardware design to perform the data acquisition. Using a broadband Minimum Variance Distortionless Response (MVDR) beamformer with Forward-Backward Spatial Smoothing (FB-SS), the sensor is able to create both 2D and 3D ultrasound images of the full-frontal hemisphere with high angular accuracy with up to 70dB main lobe to side lobe ratio. This paper describes both the hardware infrastructure needed to obtain such highly detailed acoustical images, as well as the signal processing chain needed to convert the raw acoustic data into said images. Utilizing this novel high-resolution ultrasound imaging sensor, we wish to investigate the limits of both passive and active airborne ultrasound sensing by utilizing this virtually artifact-free imaging modality.
Signal Processing,Sound,Audio and Speech Processing
What problem does this paper attempt to address?
### Problems Addressed by the Paper The paper primarily addresses the following issues: 1. **Need for High Resolution and Dynamic Range**: Over the past decade, although many airborne ultrasonic sensors have been proposed for robotic applications, these sensors typically use reduced-aperture microphone arrays (with the number of microphones usually ranging from 1 to 64) due to cost and complexity constraints. This results in generated 3D images having artifacts or limited dynamic range and spatial resolution. This paper aims to develop a sensor with high spatial resolution and high dynamic range. 2. **Dense Large-Aperture Microphone Array**: The paper introduces a novel airborne ultrasonic sensor that contains 1024 microphones arranged in a 32×32 uniform matrix array, combined with a distributed embedded hardware design for data acquisition. By using a broadband minimum variance distortionless response (MVDR) beamformer with forward-backward spatial smoothing (FB-SS), this sensor can create 2D and 3D ultrasonic images of the entire front hemisphere, with a main lobe to side lobe ratio of up to 70 dB. 3. **Study of Artifact-Free Imaging Modes**: Utilizing this high-resolution ultrasonic imaging sensor, researchers hope to explore the limits of passive and active airborne ultrasonic sensing in real-world environments and evaluate the relative importance of diffracted echoes in practical settings. In summary, this paper aims to overcome the limitations of existing sensors by developing a high-resolution, high dynamic range airborne ultrasonic sensor, thereby improving image quality and imaging performance.