On the Effectiveness of Observations in the Mid-Infrared Wavelength Range on the 2.5-Meter Telescope of the Caucasus Mountain Observatory of Moscow State University with Commercial IR Cameras

S. G. Zheltoukhov,A. M. Tatarnikov
DOI: https://doi.org/10.3103/S0027134922060133
2024-01-23
Abstract:The main factors that influence the success of observations in the infrared range (central wavelengths of the photometric bands at 3.75 and 4.8~$\mu$m) on the multipurpose optical telescope are considered. Estimates of the sky background brightness are obtained for the Caucasus Mountain Observatory (CMO) of Moscow State University: $1.3\cdot10^6$~photons/(s pixel) in the 3.75~$\mu$m band and $3.4\cdot10^6$~photons/(s pixel) in the 4.8~$\mu$m; and the instrumental background for the 2.5-m CMO telescope at $0^\circ$C: $3.2\cdot10^6$~photons/(s pixel) in the 3.75~$\mu$m band and $4.3\cdot10^6$~photons/(s pixel) in the 4.8~$\mu$m band. It is shown that at this background signal level with the currently available commercial cameras in the $3-5$~$\mu$m spectral range, the telescope-camera coupling capabilities for observing faint objects will still be limited by the thermal background. For different observational conditions, estimates of the limiting magnitudes of objects available for observations in the 3.75 and 4.8~$\mu$m ranges are obtained. For average observation conditions (instrument temperature of $0^\circ$C and stellar image size of 1 arcsec), the limit is $\sim10.6^m$ and $\sim8.4^m$, respectively.
Instrumentation and Methods for Astrophysics
What problem does this paper attempt to address?
### Problems the paper attempts to solve The paper aims to evaluate and determine the influence of the background signal on the observational capabilities when using a commercial mid - infrared (3 - 5 µm) camera for observations on the 2.5 - meter general - purpose optical telescope at the Caucasus Mountain Observatory (CMO). Specifically, the paper mainly focuses on the following issues: 1. **Estimation of background brightness**: - Calculate the sky background brightness and the instrument background brightness, especially the photon fluxes in the 3.75 µm and 4.8 µm bands. - Determine the limitations of these background signals on the ability to observe faint celestial bodies. 2. **Analysis of the sources of background signals**: - Analyze the contributions of the Earth's atmosphere, the telescope structure, and the internal components of the infrared camera to the background signals. - In particular, the influence of thermal background radiation and how it affects the observational effect. 3. **Calculation of the limiting magnitude for observations**: - Calculate the limiting magnitude under different observational conditions according to the background signal level. - Evaluate the influence of different conditions (such as telescope temperature, filter temperature, image quality, etc.) on the observational limit. 4. **Optimization of camera design**: - Propose a simplified design scheme to reduce the instrument background signal while maintaining the cost - effectiveness of the system. - Reduce the influence of reflected radiation by optimizing the positions of the filter and the diaphragm. ### Main conclusions Through a detailed analysis of the background signal, the author draws the following conclusions: - Under the current conditions, when the commercial mid - infrared camera is combined with the 2.5 - meter telescope, the ability to observe faint celestial bodies is still limited by the thermal background. - For the average observational conditions (an instrument temperature of 0°C and a stellar image size of 1 arc second), the limiting magnitude in the 3.75 µm band is approximately magnitude 10.6, and the limiting magnitude in the 4.8 µm band is approximately magnitude 8.4. - In order to improve the observational ability, it is necessary to further optimize the designs of the telescope and the camera, especially to reduce the influence of thermal background radiation. ### Formula summary The key formulas involved in the paper include: - **Photon flux calculation formula**: \[ N_{\text{ph}} = \Omega a^2 \int_{\lambda_1}^{\lambda_2} \frac{\lambda}{hc^2} \frac{1}{\exp\left(\frac{hc}{\lambda kT}\right) - 1} d\lambda \] where \( \Omega \) is the angular area, \( a \) is the pixel linear dimension, \( T \) is the temperature, \( h \) is the Planck constant, \( c \) is the speed of light, and \( k \) is the Boltzmann constant. - **Signal - to - noise ratio formula**: \[ \text{SNR} = \frac{F_0 \cdot 2.512^{-m} \cdot t_p}{\sqrt{F_0 \cdot 2.512^{-m} \cdot t + 2 \left( \left( \frac{a_s}{a_{\text{pix}}} \right)^2 \cdot F_{\text{bg}} \cdot t + \left( \frac{a_s}{a_{\text{pix}}} \right)^2 \cdot \sigma_d^2 / n \right)}} \] where \( t \) is the signal accumulation time, \( F_0 \) is the number of photoelectrons received from a magnitude 0 star, \( m \) is the target magnitude, \( F_{\text{bg}} \) is the number of background photoelectrons, \( a_s \) and \( a_{\text{pix}} \) are the sizes of the stellar image and the pixel respectively, and \( n \) is the number of single frames used to synthesize the final image. Through these studies, the paper provides important reference data and technical suggestions for future mid - infrared observations.