Xenon-gas ionization chamber to improve particle identification of heavy ion beams with Z>70

Masahiro Yoshimoto,Naoki Fukuda,Riku Matsumura,Daiki Nishimura,Hideaki Otsu,Yohei Shimizu,Toshiyuki Sumikama,Hiroshi Suzuki,Hiroyuki Takahashi,Hiroyuki Takeda,Junki Tanaka,Koichi Yoshida
2024-07-09
Abstract:In conventional ionization chambers (ICs) using P-10 (Ar+CH4) gas, as the atomic number (Z) of the ion beams increases in the energy region of 200-300 MeV/u, the Z resolution deteriorates rapidly when Z>70. This degradation is attributed to substantial energy loss straggling caused by charge state fluctuation when the beams traverse a gas medium. The energy loss straggling increases when the beams cannot attain charge state equilibrium in the IC gas. In this study, a xenon-based gas (Xe+CH4), exhibiting a sufficiently large charge state changing cross section, was used in the IC to reach charge state equilibrium. The responses of ICs with P-10 and the xenon-based gases were examined using 238U beams and cocktail radioactive isotope (RI) beams with Z=40-90 at the RI Beam Factory (RIBF). For 238U beams at 165-344 MeV/u, the P-10 gas IC yielded an energy resolution of 1.9-3.0% in full width at half maximum (FWHM), which proved inadequate for Z identification in the uranium region. In contrast, the xenon-based gas IC demonstrated a satisfactory energy resolution of 1.4-1.6%. When using cocktail RI beams, a Z resolution of 1.28 and 0.74 was achieved by the P-10 and the xenon-based gas ICs, respectively, for beams with Z=84-88 at 200 MeV/u. The contrast in Z resolutions between the P-10 and the xenon-based gas ICs was effectively elucidated by the energy loss straggling model, incorporating collisional straggling and straggling due to charge state changes in the IC gases. The xenon-based gas IC, with more than 3sigma Z separation across a broad Z range (Z=40-90), emerged as a practical solution for Z identification of heavy ion beams.
Instrumentation and Detectors,High Energy Physics - Experiment,Nuclear Experiment
What problem does this paper attempt to address?
The paper attempts to address the issue of significant degradation in Z resolution when identifying heavy ion beams with atomic numbers (Z) greater than 70 using a conventional P-10 gas (argon + methane) ionization chamber (IC) in the high-energy region (200–300 MeV/u). Specifically: 1. **Z Resolution Deterioration**: In conventional P-10 gas ionization chambers, Z resolution rapidly worsens as the atomic number of the ion beam increases, particularly when Z is greater than 70. 2. **Energy Loss Scattering**: This deterioration is mainly due to increased energy loss scattering caused by charge state fluctuations of the ion beam as it passes through the gas medium. 3. **Improvement Proposal**: To overcome this issue, the research team proposed a new xenon-based gas (Xe+CH4), which has a larger charge state change cross-section and can achieve charge state equilibrium in the ionization chamber, thereby improving Z resolution. 4. **Experimental Validation**: Experimental validation was conducted using radioactive isotope (RI) beams with different atomic numbers (Z=40–90) and a 238U beam at the RI Beam Factory (RIBF). The results showed that the xenon-based gas ionization chamber significantly outperformed the conventional P-10 gas ionization chamber in terms of Z resolution.