Risk Factors for Implant Failure of Intertrochanteric Fractures with Lateral Femoral Wall Fracture after Intramedullary Nail Fixation.
Jixing Fan,Xiangyu Xu,Fang Zhou,Zhishan Zhang,Yun Tian,Hongquan Ji,Yan Guo,Yang Lv,Zhongwei Yang,Guojin Hou
DOI: https://doi.org/10.1016/j.injury.2021.07.025
IF: 2.687
2021-01-01
Injury
Abstract:Introduction: Few studies have specifically evaluated the comminution extent of lateral femoral wall (LFW) fracture and risk factors of implant failure in intertrochanteric fractures with LFW fracture. The aim of present study was to evaluate the influence of comminution extent of LFW fracture on implant failure and identify risk factors of implant failure in cases with LFW fracture after intramedullary fixation. Methods: This retrospective study included 130 intertrochanteric fracture with LFW fracture treated with intramedullary fixation at a teaching hospital over a 13-year period from January 2006 to December 2018. Demographic information, cortical thickness index, the reduction quality, status of medial support, position of the screw/blade and status of lateral femoral wall were collected and compared. The logistic regression analyzes was performed to evaluate risk factors of implant failure in intertrochanteric fractures with LFW fracture after intramedullary nail fixation. Results: 10 patients (7.69%) suffered from mechanical failure after intramedullary fixation. Univariate analyzes showed that comminuted LFW fracture (OR, 7.625; 95%CI, 1.437 similar to 40.446; p = 0.017), poor reduction quality (OR, 49.375; 95%CI, 7.217 similar to 337.804; p < 0.001) and loss of medial support (OR, 17.818; 95%CI, 3.537 similar to 89.768; p < 0.001) were associated with implant failure. After adjustment for confounding variables, the multivariable logistic regression analyzes showed that poor reduction quality (OR, 11.318; 95%CI, 1.126 similar to 113.755; p = 0.039) and loss of medial support (OR, 7.734; 95%CI, 1.062 similar to 56.327; p = 0.043) were independent risk factors for implant failure. Whereas, comminuted LFW fracture was not associated with implant failure (p = 0.429). Conclusions: The comminution extent of the LFW fracture might influence the stability of intertrochanteric fractures; and intramedullary fixation might be an effective treatment method. Furthermore, poor reduction quality and loss of medial support could increaze the risk of implant failure in intertrochanteric fractures with LFW fractures after intramedullary fixation. Therefore, we should pay great emphasis on fracture reduction quality in future. (C) 2021 Elsevier Ltd. All rights reserved.