Optimization of an Optical Testbed for Characterization of EXCLAIM u-Spec Integrated Spectrometers

Maryam Rahmani,Emily M. Barrentine,Eric R. Switzer,Alyssa Barlis,Ari D. Brown,Giuseppe Cataldo,Jake A. Connors,Negar Ehsan,Thomas M. Essinger-Hileman,Henry Grant,James Hays-Wehle,Wen-Ting Hsieh,Vilem Mikula,S. Harvey Moseley,Omid Noroozian,Manuel A. Quijada,Jessica Patel,Thomas R. Stevenson,Carole Tucker,Kongpop U-Yen,Carolyn G. Volpert,Edward J. Wollack
2023-12-13
Abstract:We describe a testbed to characterize the optical response of compact superconducting on-chip spectrometers in development for the Experiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM) mission. EXCLAIM is a balloonborne far-infrared experiment to probe the CO and CII emission lines in galaxies from redshift 3.5 to the present. The spectrometer, called u-Spec, comprises a diffraction grating on a silicon chip coupled to kinetic inductance detectors (KIDs) read out via a single microwave feedline. We use a prototype spectrometer for EXCLAIM to demonstrate our ability to characterize the spectrometers spectral response using a photomixer source. We utilize an on-chip reference detector to normalize relative to spectral structure from the off-chip optics and a silicon etalon to calibrate the absolute frequency.
Instrumentation and Methods for Astrophysics
What problem does this paper attempt to address?
The problem that this paper attempts to solve is to optimize an optical test platform to characterize the optical response of the µ - Spec integrated spectrometer used in the EXCLAIM (Experiment for Cryogenic Large - Aperture Intensity Mapping) mission. Specifically, the research team hopes to accurately measure and calibrate the spectral response characteristics of the spectrometer through this test platform, ensuring that its performance in the far - infrared band meets the requirements of scientific goals. ### Specific problems include: 1. **Characterization of spectral response**: How to accurately measure the spectrometer's response to optical signals of different frequencies. 2. **Absolute frequency calibration**: How to ensure that the frequency measurement accuracy of the spectrometer reaches ±0.1 GHz to meet the scientific requirements of the EXCLAIM mission. 3. **Normalization of relative response**: How to eliminate the interference introduced by external optical components (such as lenses, mirrors, etc.) to ensure that the measurement results reflect the performance of the spectrometer itself. ### Main methods and techniques: - **Photomixer Source**: Use a 780 - nm GaAs photomixer to generate tunable narrow - band terahertz optical signals for scanning the spectrometer's response. - **Reference Detector**: Divide the incident optical signal into two parts through a micro - strip power divider, with one part entering the spectrometer and the other part entering the reference KID for normalizing the relative response. - **Silicon Etalon**: Used for absolute frequency calibration to ensure the frequency measurement accuracy of the spectrometer. - **Readout System**: Use the ROACH2 system and IF - box for microwave readout of KID to ensure high signal - to - noise ratio and stability of the signal. Through these technical means, the research team aims to provide a reliable optical test platform for the EXCLAIM mission, ensuring that its spectrometer can accurately measure CO and [CII] emission lines in space, thereby studying the star formation rate in galaxies.