Interferometric apodization by homothety -- II. Experimental validation

J Chafi,Y El Azhari,O Azagrouze,A Jabiri,A Boskri,Z Benkhaldoun,A Habib
DOI: https://doi.org/10.1093/mnras/stad3642
2023-12-09
Abstract:This work presents the results of experimental laboratory tests on the apodization of circular and rectangular apertures using the Interferometric Apodization by Homothety (IAH) technique. The IAH approach involves splitting the amplitude of the instrumental PSF into two equal parts. One of the two produced PSFs undergoes a homothety to change its transverse dimensions while its amplitude is properly controlled. The two PSFs are then combined to produce an apodized image. The diffraction wings of the resulting PSF are subsequently reduced by some variable reduction factor, depending on an amplitude parameter $\gamma$ and a spread parameter $\eta$. This apodization approach was implemented in the laboratory using an interferometric setup based on the Mach-Zehnder Interferometer (MZI). The experimental results exhibit a strong agreement between theory and experiment. For instance, the average experimental contrast obtained at a low angular separation of $2.4\lambda/D$ does not exceed $5\times10^{-4}$. This work also allowed us to study the influence on the apodizer's performance of some parameters such as the wavelength and the density of the neutral filters.
Instrumentation and Methods for Astrophysics
What problem does this paper attempt to address?
The problem that this paper attempts to solve is to experimentally verify the effectiveness of using the "Interferometric Apodization by Homothety (IAH)" technique for pupil masking of circular and rectangular pupils. Specifically, the IAH technique aims to reduce diffraction wings and improve the quality of high - dynamic - range imaging by changing the lateral size of the instrument point - spread function (PSF) and controlling its amplitude. ### Main problems and goals 1. **Verify the effectiveness of the IAH technique**: - Verify the feasibility of the IAH technique in a laboratory environment through experiments. - Examine the consistency between theoretical predictions and actual experimental results. 2. **Study the influence of parameters on performance**: - Explore the influence of parameters such as wavelength and neutral - density - filter density on the performance of the IAH technique. - Pay special attention to the chromatic response at different wavelengths. 3. **Improve high - resolution imaging capabilities**: - Reduce diffraction wings through the IAH technique to improve imaging contrast, especially in the case of low angular separation (for example, the contrast at 2.4 λ/D does not exceed 5 × 10^-4). ### Experimental methods - **Experimental setup**: Based on the Mach - Zehnder Interferometer (MZI), including two half - reflecting beam splitters (BS1 and BS2), two plane mirrors (M1 and M2), and circular or rectangular pupils and neutral - density filters for controlling the beam diameter and intensity. - **Data acquisition and processing**: Use a high - resolution CCD camera to capture images and perform processing such as dark - current correction through the AstroImageJ interface. ### Key formulas The core of the IAH technique lies in two coherently superimposed PSFs, one of which is stretched (with a stretching factor of η) and multiplied by an amplitude factor γ. The amplitude of the output channel is expressed as follows: \[ A(u, v, \gamma, \eta) = \frac{\sin(\pi u)}{\pi u} \frac{\sin(\pi v)}{\pi v} + \gamma \frac{\sin(\pi u \eta)}{\pi u \eta} \frac{\sin(\pi v \eta)}{\pi v \eta} \] For the anti - phase channel, the anti - phase amplitude can be obtained by simply replacing γ with -γ. ### Experimental results - **Rectangular pupil**: The experimental results show that the secondary diffraction lobes are significantly reduced in the x - and y - axes and diagonal directions, achieving about 91.8% of the energy concentrated within the central diffraction lobe, which is a significant improvement compared to 81.5% in the unmasked case. - **Circular pupil**: The experiment verifies the effectiveness of the IAH technique on circular pupils, especially achieving good contrast under low - angular - separation conditions. In conclusion, this paper experimentally verifies the effectiveness and superiority of the IAH technique on pupils of different geometric shapes, providing theoretical and technical support for further application in large - scale astronomical telescopes and other high - resolution imaging systems.