High gradients at SRF photoinjector cavities with low RRR copper cathode plug screwed to the cavity back wall

E. Vogel,J. Sekutowicz,D. Bazyl,T. Büttner,B. van der Horst,J. Iversen,D. Klinke,A. Muhs,D. Reschke,S. Sägebarth,P. Schilling,M. Schmökel,L. Steder,J.-H. Thie,H. Weise,M. Wiencek
2023-10-05
Abstract:In recent years we increased the typical maximum peak field on axis gradients obtained in L-band superconducting RF (SRF) photoinjector cavities at vertical tests to around 55 MV/m. This was achieved with niobium cathode plugs directly screwed to the cavity back wall omitting an RF choke filter and a load lock system for cathodes. Copper demonstrated being a suitable cathode material in normal conducting injector cavities used at X-Ray Free Electron Lasers (XFELs) operating with pulsed RF. In this article we present the first experimental confirmation that peak field on axis gradients around 55 MV/m and beyond can be achieved in L-band SRF photoinjector cavities with copper cathode plugs screwed to the cavity back wall. We view this as a major milestone for the development of a high gradient photoinjector operating continuous wave (CW).
Accelerator Physics
What problem does this paper attempt to address?