Development of Dual-Gain SiPM Boards for Extending the Energy Dynamic Range

Daniel Shy,Richard S. Woolf,Eric A. Wulf,Clio C. Sleator,Mary Johnson-Rambert,W. Neil Johnson,J. Eric Grove,Bernard F. Phlips
DOI: https://doi.org/10.1109/TNS.2023.3316751
2023-08-31
Abstract:Astronomical observations with gamma rays in the range of several hundred keV to hundreds of MeV currently represent the least explored energy range. To address this so-called MeV gap, we designed and built a prototype CsI:Tl calorimeter instrument using a commercial off-the-shelf (COTS) SiPMs and front-ends which may serve as a subsystem for a larger gamma-ray mission concept. During development, we observed significant non-linearity in the energy response. Additionally, using the COTS readout, the calorimeter could not cover the four orders of magnitude in energy range required for the telescope. We, therefore, developed dual-gain silicon photomultiplier (SiPM) boards that make use of two SiPM species that are read out separately to increase the dynamic energy range of the readout. In this work, we investigate the SiPM's response with regards to active area ($3\times3 \ \mathrm{mm}^2$ and $1 \times 1 \ \mathrm{mm}^2$) and various microcell sizes ($10$, $20$, and $35 \ \mu \mathrm{m}$). We read out $3\times3\times6 \ \mathrm{cm}^3$ CsI:Tl chunks using dual-gain SiPMs that utilize $35 \ \mu \mathrm{m}$ microcells for both SiPM species and demonstrate the concept when tested with high-energy gamma-ray and proton beams. We also studied the response of $17 \times 17 \times 100 \ \mathrm{mm}^3$ CsI bars to high-energy protons. With the COTS readout, we demonstrate a sensitivity to $60 \ \mathrm{MeV}$ protons with the two SiPM species overlapping at a range of around $2.5-30 \ \mathrm{MeV}$. This development aims to demonstrate the concept for future scintillator-based high-energy calorimeters with applications in gamma-ray astrophysics.
Instrumentation and Methods for Astrophysics,Instrumentation and Detectors
What problem does this paper attempt to address?
The main problem that this paper attempts to solve is to expand the energy dynamic range of gamma - ray detectors used for astronomical observations, especially in the energy range from several hundred keV to several hundred MeV, which is known as the "MeV gap". Currently, this energy range is one of the least explored regions in the astronomical sky. To meet this challenge, the research team designed and built a prototype CsI:Tl calorimeter instrument, using commercially available silicon photomultipliers (SiPMs) and front - end read - out circuits. However, during the development process, they observed significant non - linearity in the energy response, and the calorimeter using commercially available read - out circuits could not cover the four - order - of - magnitude energy range required by the telescope. Therefore, they developed a dual - gain silicon photomultiplier (SiPM) board, using two different types of SiPMs for separate read - outs to increase the read - out energy dynamic range. Specifically, the study solved the problem in the following ways: 1. **Developing a dual - gain SiPM board**: By using two SiPMs with different characteristics (one optimized for the low - energy range and the other for high - energy events), each having a different effective area and possibly mixed micro - cell sizes, to reduce the saturation of SiPMs and electronics. 2. **Experimental verification**: Experiments were carried out at the High - Intensity Gamma - ray Source (HIGS) facility and the Crocker Nuclear Laboratory at the University of California, Davis, to test the responses of these custom - made SiPMs to gamma - rays and high - energy protons. 3. **Data analysis and correction**: By analyzing the experimental data, the overlap of the two SiPMs in the energy range from 2.6 to 20 MeV was demonstrated, and the data of the two SiPMs were unified through linear correction, thus verifying the effectiveness of the dual - gain concept. Ultimately, this study aims to provide technical support for future high - energy calorimeters based on scintillators, especially for applications in the field of gamma - ray astrophysics.