The Performance of AC-coupled Strip LGAD developed by IHEP

Weiyi Sun,Mengzhao Li,Zhijun Liang,Mei Zhao,Xiaoxu Zhang,Tianyuan Zhang,Yuan Feng,Shuqi Li,Xinhui Huang,Yunyun Fan,Tianya Wu,Xuan Yang,Bo Liu,Wei Wang. Yuekun Heng,Gaobo Xu,João Guimaraes da Costa
2024-05-02
Abstract:The AC-coupled Strip LGAD (Strip AC-LGAD) is a novel LGAD design that diminishes the density of readout electronics through the use of strip electrodes, enabling the simultaneous measurement of time and spatial information. The Institute of High Energy Physics has designed a long Strip AC-LGAD prototype with a strip electrode length of 5.7 mm and pitches of 150 $\mu m$, 200 $\mu m$, and 250 $\mu m$. Spatial and timing resolutions of the long Strip AC-LGAD are studied by pico-second laser test and beta source tests. The laser test demonstrates that spatial resolution improves as the pitch size decreases, with an optimal resolution achieved at 8.3 $\mu$m. Furthermore, the Beta source test yields a timing resolution of 37.6 ps.
Instrumentation and Detectors,High Energy Physics - Experiment,Nuclear Experiment
What problem does this paper attempt to address?