3D-Printed Sheet Jet for Stable Megahertz Liquid Sample Delivery at X-ray Free Electron Lasers

Patrick E. Konold,Tong You,Johan Bielecki,Joana Valerio,Marco Kloos,Daniel Westphal,Alfredo Bellisario,Tej Varma,August Wolter,Jayanath C. P. Koliyadu,Faisal H.M. Koua,Romain Letrun,Adam Round,Tokushi Sato,Petra Mésźaros,Leonardo Monrroy,Jennifer Mutisya,Szabolcs Bódizs,Taru Larkiala,Amke Nimmrich,Roberto Alvarez,Richard Bean,Tomas Ekeberg,Richard A. Kirian,Sebastian Westenhoff,Filipe R. N. C. Maia
DOI: https://doi.org/10.1107/S2052252523007972
2023-06-13
Abstract:X-ray Free Electron Lasers (XFELs) can probe chemical and biological reactions as they unfold with unprecedented spatial and temporal resolution. A principal challenge in this pursuit is the delivery of samples to the X-ray interaction point in a way that produces data of the highest possible quality and efficiency. This is hampered by constraints posed by the light source and operation within a beamline environment. For liquid samples, the solution typically involves a high-speed liquid jet, capable of keeping up with the rate of X-ray pulses. However, conventional jets are not ideal because of radiation-induced explosions of the jet, as well as their cylindrical geometry combined with the X-ray pointing instability of many beamlines causes the interaction volume to differ for every pulse. This complicates data analysis and contributes to measurement errors. An alternative geometry is a liquid sheet jet which, with its constant thickness over large areas, eliminates the X-ray pointing related problems. Since liquid sheets can be made very thin, the radiation-induced explosion is reduced, boosting their stability. They are especially attractive for experiments which benefit from small interaction volumes such as fluctuation X-ray scattering and several types of spectroscopy. Although they have seen increasing use for soft X-ray applications in recent years, there has not yet been wide-scale adoption at XFELs. Here, we demonstrate liquid sheet jet sample injection at the European XFEL. We evaluate several aspects of its performance relative to a conventional liquid jet including thickness profile, stability, and radiation-induced explosion dynamics at high repetition rates. The sheet jet exhibits superior performance across these critical experimental parameters. Its minute thickness also suggests ultrafast single-particle solution scattering is a possibility.
Instrumentation and Detectors,Applied Physics,Biological Physics
What problem does this paper attempt to address?
The problem that this paper attempts to solve is to achieve stable and efficient liquid sample delivery in X - ray free - electron lasers (XFELs). Specifically, the research aims to overcome the challenges encountered when applying existing liquid jetting techniques in high - repetition - rate XFEL beamlines (such as the SPB/SFX nanofocusing beamline of the European XFEL), especially how to reduce background fluctuations, improve sample - delivery stability, and reduce radiation - induced jet explosions. These problems are crucial for improving data quality and experimental efficiency, especially on high - repetition - rate beamlines that require continuous - flow sample delivery. ### Main problems: 1. **Background fluctuations**: - The cylindrical droplet jets produced by the conventional gas - dynamic virtual nozzle (GDVN) lead to significant background fluctuations, which affect the quality and reliability of the data. These fluctuations are partly due to the instability of the X - ray beam pointing. 2. **Sample - delivery stability**: - Sample delivery at a high repetition rate requires a highly stable jet to ensure that each pulse can effectively interact with the sample. Traditional jetting methods are prone to instability at high repetition rates, such as jet interruption or jet - mode changes. 3. **Radiation - induced jet explosions**: - High - intensity X - ray pulses can trigger jet explosions, which not only destroy the stability of the jet but also may lead to sample loss and experimental interruption. Traditional jetting methods are difficult to maintain stable operation for a long time in such a high - energy environment. ### Solutions: The paper proposes a liquid sheet jet method based on 3D printing technology to solve the above problems. This method has the following advantages: 1. **Reduce background fluctuations**: - The liquid sheet jet has a constant thickness and extremely high flatness, which reduces the influence of X - ray beam - pointing instability on the data, thereby reducing background fluctuations. 2. **Improve sample - delivery stability**: - The liquid sheet jet exhibits higher stability at a high repetition rate, and its jetting mode is more consistent, reducing data - quality problems caused by jet interruption or mode changes. 3. **Reduce radiation - induced jet explosions**: - Since the liquid sheet jet is relatively thin, the radiation - induced explosion effect is significantly weakened, improving the stability of the jet at a high repetition rate. Through these improvements, the liquid sheet jet method is expected to achieve higher - quality data acquisition and more efficient experimental operations on high - repetition - rate XFEL beamlines, especially in experiments that require precise control of sample - beam interactions.