Optical Truss Interferometer for the LISA Telescope

Kylan Jersey,Ian Harley-Trochimczyk,Yanqi Zhang,Felipe Guzman
DOI: https://doi.org/10.1364/AO.493108
2023-07-22
Abstract:The LISA telescopes must exhibit an optical path length stability of $\frac{\mathrm{pm}}{\sqrt{\mathrm{Hz}}}$ in the mHz observation band to meet mission requirements. The optical truss interferometer is a proposed method to aid in the ground testing of the telescopes, as well as a risk-mitigation plan for the flight units. This consists of three Fabry-Perot cavities mounted to the telescope which are used to monitor structural displacements. We have designed and developed a fiber-based cavity injection system that integrates fiber components, mode-matching optics, and a cavity input mirror into a compact input stage. The input stages, paired with return mirror stages, can be mounted to the telescope to form the optical truss cavities. We performed a thorough sensitivity analysis using various simulation methods to support the fabrication and assembly of three first-generation prototype cavities, each of which exhibited a satisfactory performance based on our models.
Optics,Instrumentation and Methods for Astrophysics
What problem does this paper attempt to address?