Programmable Transimpedance Amplifier with Integrated Bandgap Reference for Glucose Concentration Measurement

Riyaz Ahmad,Amit M. Joshi,Dharmendra Boolchandani
2023-05-22
Abstract:For glucose electrochemical sensors, a comprehensive electronics interface is designed and constructed in 0.18 um, CMOS process technology, and 1.5 V supply voltage. This interface includes a programmable readout amplifier and bandgap reference voltage potentiostat circuit. The programmable transimpedance amplifier (PTIA), the proposed readout circuit, provides a large dynamic range and low noise. The overall transimpedance increase for the PTIA is 17.3-50.5 kohm. For an input current range of 4.2-180 uA, the PTIA response has a linear output voltage range of 0.55-1.44 V. The output rms noise value is calculated to be 5.101 Vrms, and the overall power consumption of the design is 2.33 mW. The THD percentage spans from 7.6 to 10.2 in the current range mentioned above. All bandgap reference voltage potentiostat measurements are made using the reference potential of 0.6 V. The working electrode was a glassy carbon electrode (GCE) loaded with a CuO/Cu0:76CO2:25O4 (copper cobaltite) coating. An electrochemical glucose sensing setup has been used to measure glucose concentrations between 1 and 10 mM, and an emulated circuit has been used to verify the viability of the proposed glucose sensing design. The suggested glucose sensor architecture has a total size of 0.0684 mm2.
Systems and Control
What problem does this paper attempt to address?
The paper aims to design and construct a comprehensive electronic interface for measuring glucose concentration. Specifically, the interface is designed and constructed using 0.18-micron CMOS process technology and a 1.5V power supply voltage, including a Programmable Transimpedance Amplifier (PTIA) and a bandgap reference voltage potentiometer circuit. The key issues the paper attempts to address are improving the dynamic range of the glucose sensor, reducing noise, and ensuring a linear output voltage response. ### Main Issues: 1. **Improving Dynamic Range**: The proposed design needs to handle a wide range of glucose concentrations to enhance the sensor's sensitivity and linearity. 2. **Reducing Noise**: The readout circuit design needs to have low noise characteristics to ensure the accuracy of the measurement results. 3. **Linear Output Voltage**: For an input current range of 4.2-180µA, the readout circuit needs to provide a linear output voltage range (0.55-1.44 V). 4. **Low Power Consumption**: The total power consumption of the entire design should be controlled at a low level (2.33 mW). 5. **High Precision**: The total harmonic distortion (THD) of the design should be between 7.6% and 10.2% to ensure the reliability of the measurements. ### Solutions: - **Programmable Transimpedance Amplifier (PTIA)**: This amplifier provides a large dynamic range and low noise, with a total transimpedance gain range of 17.3-50.5 kΩ. - **Bandgap Reference Voltage Potentiometer**: Provides a stable reference voltage (0.6 V) to ensure the stability and accuracy of the circuit. - **Current Mode (CM) Circuit**: Compared to voltage mode (VM) circuits, current mode circuits have lower power consumption and better performance. - **Experimental Verification**: The effectiveness of the design was verified through circuit simulation and actual measurements, capable of accurate measurement within a glucose concentration range of 1-10 mM. ### Conclusion: The paper proposes a novel electronic interface architecture suitable for glucose sensing applications. The design is implemented using 0.18-micron CMOS process technology and features programmability, a large dynamic range, low power consumption, and a wide glucose detection range. These characteristics make the design highly practical for real-world applications.