Protocols for healing radiation-damaged single-photon detectors suitable for space environment

Joanna Krynski,Nigar Sultana,Youn Seok Lee,Vadim Makarov,Thomas Jennewein
DOI: https://doi.org/10.1109/TNS.2023.3332830
2023-12-08
Abstract:Single-photon avalanche detectors (SPADs) are well-suited for satellite-based quantum communication because of their advantageous operating characteristics as well as their relatively straightforward and robust integration into satellite payloads. However, space-borne SPADs will encounter damage from space radiation, which usually manifests itself in the form of elevated dark counts. Methods for mitigating this radiation damage have been previously explored, such as thermal and optical (laser) annealing. Here we investigate in a lab, using a CubeSat payload, laser annealing protocols in terms of annealing laser power and annealing duration, for their possible later use in orbit. Four Si SPADs (Excelitas SLiK) irradiated to an equivalent of 10 years in low Earth orbit exhibit very high dark count rates (>300 kcps at -22 C operating temperature) and significant saturation effects. We show that annealing them with optical power between 1 and 2 W yields reduction in dark count rate by a factor of up to 48, as well as regaining SPAD sensitivity to a very faint optical signal (on the order of single photon) and alleviation of saturation effects. Our results suggest that an annealing duration as short as 10 seconds can reduce dark counts, which can be beneficial for power-limited small-satellite quantum communication missions. Overall, annealing power appears to be more critical than annealing duration and number of annealing exposures.
Space Physics,Instrumentation and Methods for Astrophysics,Instrumentation and Detectors
What problem does this paper attempt to address?
The problem that this paper attempts to solve is the damage to single - photon avalanche detectors (SPADs) caused by space radiation. Specifically, when these detectors are used in satellite quantum communication, they will be affected by radiation from space, resulting in a significant increase in the dark count rate (DCR). This increased dark count rate not only reduces the signal - to - noise ratio of the signal but also may cause the detector to saturate, thus seriously affecting its performance and service life. Therefore, the main objective of the paper is to study the effectiveness of laser annealing technology in repairing these radiation damages in a laboratory environment, especially by adjusting the laser power and annealing time to optimize this process, with the hope of being able to apply these methods in actual satellite missions and extend the service life of SPADs. The paper mentions that by using a laser power of 1 to 2 watts for annealing treatment, the dark count rate can be reduced by as much as 48 times, and the sensitivity of SPADs to weak optical signals can be restored, alleviating the saturation effect. In addition, it is found that an annealing time as short as 10 seconds can effectively reduce the dark count, which is very advantageous for small - satellite quantum communication tasks with limited power. Overall, the annealing power seems to be more critical than the annealing time and the number of annealing times.