On Analysis of Laser Plasma Aluminum Monoxide Emission Spectra

Christian G. Parigger
2023-04-29
Abstract:This work communicates analysis of aluminum monoxide, AlO, laser-plasma emission records using line strength data and the ExoMol astrophysical database. A nonlinear fitting program computes comparisons of measured and simulated diatomic molecular spectra. Predicted cyanide spectra of the AlO, ${\rm B}\ ^2\,\Sigma^+ \longrightarrow {\rm X} \ ^2\,\Sigma^+$, $\Delta {\rm v} = 0, \pm 1, \pm 2, + 3$ sequences and progressions compare nicely with 1 nanometer resolution experimental results. The analysis discusses experiment data captured during laser ablation of Al$_2$O$_3$ with 266-nm, 6-mJ pulses. The accuracy of the AlO line strength data is better than one picometer. This work presents as well comparison of the $^{27}$Al$^{16}$O line strength and of ExoMol data for spectral resolutions of 0.1 nm and 0.07 nm. Accurate AlO databases show a volley of applications in laboratory and astrophysical plasma diagnosis.
Plasma Physics
What problem does this paper attempt to address?
This paper aims to analyze the laser plasma emission spectrum of aluminum monoxide (AlO). Specifically, the authors use line intensity data and the ExoMol astrophysics database to analyze and simulate the diatomic molecular spectrum of AlO. The research focuses on the B2Σ+−X2Σ+ transition system of AlO, and compares the experimentally measured and simulated diatomic molecular spectra through a non - linear fitting program. The paper mentions that the predicted AlO cyanide spectral sequences and progressions are in good agreement with the experimental results at a 1 - nm resolution. In addition, the paper also discusses the experimental data captured during the laser ablation of Al2O3, using 266 - nm, 6 - mJ pulses for ablation, and the accuracy of the AlO line intensity data is better than 1 pm. This study shows the broad application potential of an accurate AlO database in laboratory and astrophysical plasma diagnostics. The key points of the paper include: - **Research background**: Aluminum monoxide (AlO) appears in the plasma emission generated after laser ablation of aluminum - containing samples, such as aluminum oxide (Al2O3) or aluminum - containing alloys. The AlO flame emission spectrum can also be observed when burning aluminum - containing propellants. - **Data analysis methods**: Use the ExoMol database and the PGOPHER program to simulate rotational, vibrational and electronic spectra, and use the Boltzmann equilibrium spectral program (BESP) and the Nelder - Mead temperature (NMT) program to calculate the emission spectra and fit the theoretical and experimental spectra. - **Experimental setup**: The experimental data are from a frequency - quadrupled Q - switched Nd:YAG radiation laser ablation experiment, with a recording range from 430 nm to 540 nm. Measurements are made using standard laser - induced breakdown spectroscopy (LIBS) equipment. - **Results**: Through the ExoMol data and the calculated line intensity data, the ∆v = 0, ±1, ±2, +3 sequences and progressions of the B2Σ+−X2Σ+ transition system of AlO are analyzed. The results show that the ExoMol database contains 4,945,580 transitions and 94,862 states, while the AlO - lsf data contains 33,484 transitions. The accuracy of the simulated line positions is generally better than 0.05 cm−1. - **Discussion**: At a 1 - nm spectral resolution, the experimental emission spectra are analyzed using ExoMol line intensity and the NMT program, and the obtained AlO excitation temperature is approximately 3,380 K, which is consistent with the previous results analyzed using AlO - lsf line intensity. However, at a 0.07 - nm spectral resolution, there is a significant difference of about 30% between the temperature calculated by ExoMol and the temperature fitted by AlO - lsf. Overall, through detailed experimental and theoretical analyses, this paper verifies the application potential of the ExoMol database in high - resolution spectral analysis, and also points out its limitations under certain high - precision requirements.