Gas selection for Xe-based LCP-GEM detectors onboard the CubeSat X-ray observatory NinjaSat

T. Takeda,T. Tamagawa,T. Enoto,T. Kitaguchi,Y. Kato,T. Mihara,W. Iwakiri,M. Numazawa,Y. Zhou,K. Uchiyama,Y. Yoshida,N. Ota,S. Hayashi,S. Watanabe,A. Jujo,H. Sato,C.P. Hu,H. Takahashi,H. Odaka,T. Tamba,K. Taniguchi
DOI: https://doi.org/10.1088/1748-0221/18/06/C06020
2023-06-19
Abstract:We present a gas selection for Xe-based gas electron multiplier (GEM) detectors, Gas Multiplier Counters (GMCs) onboard the CubeSat X-ray observatory NinjaSat. To achieve an energy bandpass of 2-50 keV, we decided to use a Xe-based gas mixture at a pressure of 1.2 atm that is sensitive to high-energy X-rays. In addition, an effective gain of over 300 is required for a single GEM so that the 2 keV X-ray signal can be sufficiently larger than the electrical noise. At first, we measured the effective gains of GEM in nine Xe-based gas mixtures (combinations of Xe, Ar, CO2, CH4, and dimethyl ether; DME) at 1.0 atm. The highest gains were obtained with Xe/Ar/DME mixtures, while relatively lower gains were obtained with Xe/Ar/CO2, Xe/Ar/CH4, and Xe+quencher mixtures. Based on these results, we selected the Xe/Ar/DME (75%/24%/1%) mixture at 1.2 atm as the sealed gas for GMC. Then we investigated the dependence of an effective gain on the electric fields in the drift and induction gaps ranging from 100-650 V cm$^{-1}$ and 500-5000 V cm$^{-1}$, respectively, in the selected gas mixture. The effective gain weakly depended on the drift field while it was almost linearly proportional to the induction field: 2.4 times higher at 5000 V cm$^{-1}$ than at 1000 V cm$^{-1}$. With the optimal induction and drift fields, the flight model GMC achieves an effective gain of 460 with an applied GEM voltage of 590 V.
Instrumentation and Methods for Astrophysics,High Energy Physics - Experiment
What problem does this paper attempt to address?
The paper aims to address the following issues: 1. **Selecting the appropriate gas mixture**: To achieve an energy bandwidth of 2 to 50 kilo-electron volts (keV), the research team needs to select a xenon (Xe)-based gas mixture that is sensitive to high-energy X-rays at 1.2 atmospheres. Additionally, to ensure that the 2 keV X-ray signal is significantly greater than the circuit noise, a single GEM (Gas Electron Multiplier) needs to achieve an effective gain of over 300. 2. **Optimizing the electric field settings**: In the selected Xe/Ar/DME (75%/24%/1%) mixture, the effects of the electric field strengths (𝐸d and 𝐸i) in the drift gap and induction gap on the effective gain were studied to find the optimal electric field configuration. By experimentally measuring the effective gain of GEM in nine different Xe-based gas mixtures (including various combinations of Xe, Ar, CO₂, CH₄, and dimethyl ether (DME)) at 1.0 atmosphere, the Xe/Ar/DME (75%/24%/1%) mixture was ultimately chosen as the sealing gas and further tested at 1.2 atmospheres. The results showed that, under the optimal drift and induction electric field settings, the flight model GMC (Gas Multiplier Counter) could achieve an effective gain of 460.