Quasiparticle Generation-Recombination Noise in the Limit of Low Detector Volume

J. Li,P. S. Barry,T. Cecil,C. L. Chang,K. Dibert,R. Gualtieri,M. Lisovenko,Z. Pan,V. Yefremenko,G. Wang,J. Zhang
DOI: https://doi.org/10.1109/TASC.2023.3237645
2023-04-04
Abstract:We have measured the quasiparticle generation-recombination (GR) noise in aluminium lumped element kinetic inductors with a wide range of detector volumes at various temperatures. The basic detector consists of meandering inductor and interdigitated capacitor fingers. The inductor volume is varied from 2 to 153 {\mu}m^{3} by changing the inductor width and length to maintain a constant inductance. We started with measuring the power spectrum density (PSD) of the detectors frequency noise which is a function of GR noise and we clearly observed the spectrum roll off at 10 kHz which corresponds to the quasiparticle lifetime. Using data from a temperature sweep of the resonator frequency we convert the frequency fluctuation to quasiparticle fluctuation and observe its strong dependence on detector volume: detectors with smaller volume display less quasiparticle noise amplitude. Meanwhile we observe a saturated quasiparticle density at low temperature from all detectors as the quasiparticle life time {\tau}qp approaches a constant value at low temperature.
Instrumentation and Methods for Astrophysics
What problem does this paper attempt to address?