Influence of design parameters of upstream Venturi pipeline on multiphase flow measurement

Mengke Zhan,Muhammad Alif bin Razali,Ayush Moitra,Cheng-Gang Xie,Wai Lam Loh,Jian-Jun Shu
DOI: https://doi.org/10.1080/19942060.2023.2182831
2023-03-24
Abstract:A multiphase flowmeter (MPFM) is used in the upstream oil and gas industry for continuous, in-line, real-time, oil-gas-water flow measurement without fluid separation. An MPFM typically consists of phase-fraction (holdup) and velocity (or flow rate) measurements. It is desirable to have homogeneous flow at the measurement location so that the phase-fraction measurement is representative. A horizontal blind-tee pipe-section is often installed to homogenize flow in the downstream vertical Venturi-based flowmeters; however, little information is available on the effect of horizontal blind-tee depth (HBD) on flow homogeneity. In addition, the Venturi vertical entrance length (VEL) leading to the Venturi inlet from the horizontal blind-tee outlet is another design parameter that may potentially affect the downstream phase distribution. The phase-fraction measurement principle requires liquid properties (e.g. water salinity). The local liquid richness makes the horizontal blind-tee an ideal location for measuring liquid properties; however, an excessive HBD may affect the reliability of the measurements of liquid properties, because local vortices may degrade liquid measurement representativeness if the local liquid velocity is too low. This study uses a computational fluid dynamics approach to evaluate the effect of HBD and VEL on multiphase flow measurement, including the Venturi differential-pressure, the Venturi inlet and the throat phase-fraction, and the local liquid-property at the end of a horizontal blind-tee. The computational results are validated with experimental data collected in a multiphase flow facility. Appropriate HBD and VEL are recommended.
Fluid Dynamics
What problem does this paper attempt to address?
The paper aims to address key issues in the design of multiphase flow meters (MPFM) in the upstream oil and gas industry, particularly regarding the impact of design parameters of the upstream Venturi pipeline on multiphase flow measurement. Specifically, the study focuses on two main design parameters: 1. **Horizontal Blind-Tee Depth (HBD)**: This refers to the distance from the end of the horizontal blind-tee to the centerline of the vertical pipeline. HBD affects local flow velocity and fluid exchange, thereby influencing the effectiveness of downstream fluid mixing. An excessively long or short HBD may impact the reliability of liquid property measurements. 2. **Vertical Entrance Length (VEL)**: This refers to the distance from the exit of the horizontal blind-tee to the entrance of the Venturi. VEL may affect downstream phase distribution, particularly the phase fraction measurement at the Venturi throat. The study evaluates the impact of these two parameters on multiphase flow measurement using Computational Fluid Dynamics (CFD) methods, including Venturi pressure drop, phase fractions at the Venturi entrance and throat, and liquid properties at the end of the horizontal blind-tee. Experimental data validated the computational results, and suitable HBD and VEL values were recommended. This research fills a gap in the study of horizontal blind-tee design in vertically installed Venturi-type multiphase flow meters.