Self-Calibrated Atom-Interferometer Gyroscope by Modulating Atomic Velocities

Hong-Hui Chen,Zhan-Wei Yao,Ze-Xi Lu,Si-Bin Lu,Min Jiang,Shao-Kang Li,Xiao-Li Chen,Chuan Sun,Yin-Fei Mao,Yang Li,Run-Bing Li,Jin Wang,Ming-Sheng Zhan
2023-03-01
Abstract:Atom-interferometer gyroscopes have attracted much attention for their potential superior long-term stability and extremely low drift. For such high precision instrument, a self-calibration to achieve an absolute rotation measurement is highly demanded. Here we propose and demonstrate a self-calibration of the atomic gyroscope. The calibration is realized by using the detuning of laser frequency to control the atomic velocity thus to modulate the scale factor of the gyroscope. The modulation determines the order and the initial phase of the interference stripe, thus eliminates the ambiguity caused by the periodicity of the interferometric signal. The calibration method is verified by measuring the Earth's rotation. Long-term stable and self-calibrated atom-interferometer gyros can find important applications in the fields of fundamental physics and long-time navigation.
Atomic Physics
What problem does this paper attempt to address?
The core problem that this paper attempts to solve is **how to achieve self - calibration of the atomic interferometer gyroscope to complete absolute rotation measurement**. Specifically, the researchers proposed a method to achieve self - calibration of the atomic interferometer gyroscope by modulating the atomic velocity, thereby eliminating the phase determination ambiguity caused by the periodicity of the interference signal and further improving the long - term stability and accuracy of the gyroscope. ### Problem decomposition solved by the paper: 1. **Eliminate phase ambiguity**: The output signal of the atomic interferometer gyroscope is periodic (formula \( \phi_D=\phi_\Omega - 2n\pi+\phi_0 \)), which will lead to the multi - valued problem of phase determination. The paper proposes to change the scale factor \( K \) by modulating the atomic velocity, so as to clearly determine the integer \( n \), and then accurately calculate the rotation - induced phase shift \( \phi_\Omega \). 2. **Achieve self - calibration**: Traditional calibration methods rely on auxiliary devices (such as turntables), but these methods may introduce additional system errors. The paper proposes a self - calibration method without auxiliary devices, that is, by precisely controlling the frequency detuning of the cooling laser to adjust the atomic velocity, thereby achieving direct calibration of the scale factor \( K \). 3. **Improve dynamic range and accuracy**: By modulating the atomic velocity, the phase shift caused by rotation can be arbitrarily calibrated, which expands the dynamic range of the system and improves the accuracy of absolute rotation measurement. The paper mentions that the relative uncertainty of the projected value of the Earth's rotation measured by this method is 162 ppm, which is better than the traditional turntable modulation method. 4. **Verify absolute rotation measurement**: The researchers verified the effectiveness of the self - calibration method by measuring the Earth's rotation and combining high - precision turntable experiments. The experimental results show that this method can determine the azimuth of the gyroscope relative to the true north direction with higher accuracy. ### Formula summary: - Definition of scale factor: \[ K=\frac{\phi_\Omega}{\Omega} \] - Rotation - induced phase shift: \[ \phi_\Omega = 4(\mathbf{k}_{\text{eff}}\cdot(\mathbf{\Omega}\times\mathbf{v}))T^2 \] - Measured differential phase shift: \[ \phi_D=\phi_\Omega - 2n\pi+\phi_0 \] - Atomic velocity measurement formula: \[ v=\frac{L}{T_R}=\frac{2\pi L(f_1 - f_2)}{\phi_1-\phi_2} \] Through the above methods, the paper has successfully solved the key problems of the atomic interferometer gyroscope in practical applications, providing an important tool for high - precision, long - term stable inertial navigation and basic physics research.