Characterization and limits of a cold atom Sagnac interferometer

A. Gauguet,Benjamin Canuel,Thomas Lévèque,Walid Chaibi,Arnaud Landragin
DOI: https://doi.org/10.1103/PhysRevA.80.063604
2009-11-18
Abstract:We present the full evaluation of a cold atom gyroscope based on atom interferometry. We have performed extensive studies to determine the systematic errors, scale factor and sensitivity. We demonstrate that the acceleration noise can be efficiently removed from the rotation signal allowing to reach the fundamental limit of the quantum projection noise for short term measurements. The technical limits to the long term sensitivity and accuracy have been identified, clearing the way for the next generations of ultra-sensitive atom gyroscopes.
Atomic Physics
What problem does this paper attempt to address?
The problem that this paper attempts to solve is to develop a cold - atom gyroscope based on an atomic interferometer and conduct a comprehensive performance evaluation on it. Specifically, the researchers focus on the following aspects: 1. **Determination of systematic errors**: The paper studies in detail various systematic errors that may affect the measurement results, such as the Zeeman effect caused by the magnetic field, the coincidence degree of atomic trajectories, the stability of atomic velocities, etc. Through these studies, the authors can correct the measurement data more accurately and improve the precision of the instrument. 2. **Measurement of scale factors**: The scale factor refers to the conversion relationship between the actual rotation or acceleration and the measured phase shift. In the paper, the linearity and quadratic dependence of the scale factor are tested by changing the rotation rate and the interaction time \(T\) to ensure the reliability of the measurement results. 3. **Improvement of sensitivity and long - term stability**: The authors explore how to reduce short - term noise and long - term drift to reach the limit of quantum projection noise, which is the theoretical limit for short - time measurements. At the same time, they also analyze the technical limitations on long - term sensitivity and accuracy, providing directions for the design of the next - generation ultrasensitive atomic gyroscopes. ### Specific problem analysis #### 1. Sources and measurement of systematic errors - **Zeeman effect**: Due to the existence of the magnetic field, the atomic energy levels of different spin states will undergo Zeeman splitting, which will cause a phase shift. In the paper, the influence of this effect is reduced by selecting the spin state of \(m_F = 0\), and the specific contribution to the phase shift is evaluated by measuring the magnetic field strength at different positions. - **Coincidence degree of atomic trajectories**: In order to reduce systematic errors, the trajectories of the two atomic sources need to coincide as much as possible. In the paper, by adjusting the experimental parameters, the coincidence degree of the two atomic clouds in the interference region is within 0.5 mm. - **Stability of atomic velocities**: The velocity stability of atoms is measured by Raman spectroscopy, and the paper shows the velocity fluctuations at different time scales, which is crucial for long - term stability analysis. #### 2. Measurement of scale factors - **Dependence on rotation rate**: By changing the angle \(\theta\) of the gyroscope relative to the east - west direction, the earth's rotation rate \(\Omega_y\) under different horizontal projections is measured. After fitting the experimental data, the rotation scale factor \(A(0)/(ΩT\sinλ) = 15124 \pm 12 \, \text{rad} \, \text{rad}^{-1} \, \text{s}^{-1}\) is obtained. - **Dependence on interaction time \(T\)**: By orienting the experimental device at a position of \(\theta \approx \pm 90^\circ\), the dependence of the rotation phase shift on \(T^2\) is tested. The results show that the phase shift has a good linear relationship with \(T^2\), verifying the theoretical expectation. #### 3. Improvement of sensitivity and long - term stability - **Removal of short - term noise**: By efficiently removing acceleration noise, the authors can reach the limit of quantum projection noise in a short time. - **Long - term stability analysis**: The paper analyzes the main limiting factors for long - term measurements, such as the stability of atomic trajectories, magnetic field fluctuations, etc., and proposes improvement measures. In conclusion, through a comprehensive evaluation of the cold - atom gyroscope, this paper solves key problems in aspects such as systematic errors, scale factors, and sensitivity, laying the foundation for the future development of high - precision inertial sensors.