Development of the normalization method for the Jagiellonian PET scanner

Aurélien Coussat,Wojciech Krzemien,Jakub Baran,Szymon Parzych
DOI: https://doi.org/10.12693/APhysPolA.142.414
2024-08-31
Abstract:This work aims at applying the theory of the component-based normalization for the Jagiellonian PET scanner, currently under development at the Jagiellonian University. In any Positron Emission Tomography acquisition, efficiency along a line-of-response can vary due to several physical and geometrical effects, leading to severe artifacts in the reconstructed image. To mitigate these effects, a normalization coefficient is applied to each line-of-response, defined as the product of several components. Specificity of the Jagiellonian PET scanner geometry is taken into account. Results obtained from GATE simulations are compared with preliminary results obtained from experimental data.
Medical Physics
What problem does this paper attempt to address?
This paper aims to solve the problem of efficiency variation in positron emission tomography (PET) imaging caused by physical and geometric effects, which can lead to severe artifacts in reconstructed images. Specifically, the paper focuses on the development of a normalization method for the Jagiellonian PET (J - PET) scanner. The J - PET scanner is a highly - accepted multi - purpose PET detector, and its design optimizes the detection ability of photons generated by positron - electron annihilation. Due to the design features of the J - PET scanner, its detector strips are continuous in the axial direction, which makes the traditional normalization method not fully applicable. Therefore, the paper proposes a component - based normalization method. By decomposing the normalization coefficient into multiple sub - components that can be estimated separately and adopting a fan - sum strategy to reduce the estimation variance, the image quality is improved. The main contributions of the paper are as follows: 1. **Definition of Normalization Coefficient**: The paper defines the normalization coefficient to compensate for the variation in detection efficiency and geometric effects not included in the projection model. The normalization coefficient consists of multiple factors, each of which takes into account different effects, such as the axial block profile factor \(b_{\text{ax}}\), the axial geometric factor \(g_{\text{ax}}\), the transverse geometric factor \(g_{\text{tr}}\), the transverse interference function \(f_{\text{tr}}\) and the intrinsic detector efficiency \(\epsilon\). 2. **Data Acquisition and Processing**: To calculate the normalization factor, the research team used the Siemens CS - 27 cylindrical phantom for data collection and carried out Monte Carlo simulations. These data are used to verify the effectiveness of the normalization method. 3. **Preliminary Results**: The paper presents the preliminary calculation results of the normalization factor, including the axial block profile factor \(b_{\text{ax}}\), the axial geometric factor \(g_{\text{ax}}\), the intrinsic detector efficiency \(\epsilon\) and the transverse geometric factor \(g_{\text{tr}}\). The results show that there are significant differences in detection efficiency at different positions, and these differences can be corrected by the normalization factor. 4. **Future Work**: The paper discusses future research directions, including interpolating the normalization factor with axial dependence to calculate the normalization factor at any point along the entire strip, and evaluating the improvement in image quality when all normalization factors are considered in the image reconstruction process. In conclusion, by developing a normalization method suitable for the J - PET scanner, this paper aims to improve the quality and accuracy of PET imaging and provide technical support for future clinical applications.