Optimization of the double electron-electron resonance for C-centers in diamond

Olga R. Rubinas,Vladimir V. Soshenko,Stepan V. Bolshedvorskii,Ivan S. Cojocaru,Vadim V. Vorobyov,Vadim N. Sorokin,Victor G. Vins,Alexander P. Yeliseev,Andrey N. Smolyaninov,Alexey V. Akimov
DOI: https://doi.org/10.1002/pssr.202100561
2021-11-05
Abstract:NV centers in diamond recommend themselves as good sensors of environmental fields as well as detectors of diamond impurities. In particular, C-centers, often also called ${{p}_{1}}$-centers, can be detected via double electron-electron resonance. This resonance can be used to measure the C-center concentration. Here, we measured the concentration of C-centers in several diamond plates and investigated the influence of the free precession time of the NV center on the observed contrast in the measured double electron-electron resonance spectrum. The dependence of the resonance amplitudes and widths on the concentration of C-centers as well as the length of the combined C-center driving and NV-center $\pi$-pulse is also discussed. The optimal contrast-free precession time was determined for each C-center concentration, showing a strong correlation with both the concentration of C-centers and the NV-center ${{T}_{2}}$ time.
Instrumentation and Detectors,Optics,Quantum Physics