The gas flow pattern through a small size Resistive Plate Chamber with 2mm gap

Yousef Pezeshkian,Amir Kiyoumarsioskouei,Majid Ahmadpouri,Ghasem Ghorbani
DOI: https://doi.org/10.1088/1748-0221/16/11/P11022
2021-09-06
Abstract:A prototype of a single-gap glass Resistive Plate Chamber (RPC) is constructed by the authors. To find the considerations required for better operation of the detector's gas system, we have simulated the flow of the Ar gas through the detector by using computational fluid dynamic methods. Simulations show that the pressure inside the chamber linearly depends on the gas flow rate and the chamber's output hose length. The simulation results were compatible with experiments. We have found that the pressure-driven speed of the gas molecules is two orders of magnitude larger in the inlet and outlet regions than the blocked corners of a 14x14 cm2 chamber, and most likely seems to be higher for larger detectors and different geometries.
Instrumentation and Detectors,Instrumentation and Methods for Astrophysics