Calibration of AstroSat/UVIT Gratings and Spectral Responses

G. C. Dewangan
DOI: https://doi.org/10.1007/s12036-021-09691-w
2021-02-04
Abstract:AstroSat/UVIT carries two gratings in the FUV channel and a single grating in the NUV channel. These gratings are useful for low resolution, slitless spectroscopy in the far and near UV bands of a variety of cosmic sources such as hot stars, interacting binaries, active galactic nuclei, etc. We present the calibration of these gratings using observations of UV standards NGC40 and HZ4. We perform wavelength and flux calibration and derive effective areas for different grating orders. We find peak effective areas of 18.7cm^2 at 2325 Angstrom for the -1 order of NUV-Grating, 4.5cm^2 at 1390 Angstrom for the -2 order of FUV-Grating1, and 4.3cm^2 at 1500 Angstrom for the -2 order of FUV-Grating2. The FWHM spectral resolution of the FUV gratings is 14.6 Angstrom in the -2 order. The -1 order of NUV grating has an FWHM resolution of 33 Angstrom. We find excellent agreement in flux measurements between the FUV/NUV gratings and all broadband filters. We have generated spectral responses of the UVIT gratings and broadband filters that can directly be used in the spectral fitting packages such as XSPEC, Sherpa, and ISIS, thus allowing spectral analysis of UVIT data either separately or jointly with X-ray data from AstroSat or other missions.
Instrumentation and Methods for Astrophysics
What problem does this paper attempt to address?
The problem that this paper attempts to solve is to calibrate the gratings in the AstroSat/UVIT spectrometer and their spectral responses. Specifically, the paper focuses on the calibration issues of the two gratings carried by UVIT in the far - ultraviolet (FUV) channel and one grating in the near - ultraviolet (NUV) channel. These gratings are suitable for low - resolution slitless spectral observations in the far - ultraviolet and near - ultraviolet bands of a variety of cosmic sources (such as hot stars, interacting binaries, active galactic nuclei, etc.). The main objectives of the paper include: 1. **Wavelength Calibration**: Use the observational data of standard ultraviolet sources NGC 40 and HZ 4 for wavelength calibration. 2. **Flux Calibration**: Conduct flux calibration by comparing with the standard star HZ 4 with a known spectrum. 3. **Effective Area Determination**: Determine the effective areas of different grating orders. 4. **Spectral Resolution**: Measure the spectral resolutions of the FUV and NUV gratings. 5. **Cross - Calibration**: Verify the consistency of flux measurements between the gratings and broadband filters. 6. **Instrument Response Generation**: Generate spectral response files that can be used in X - ray astronomy software packages (such as XSPEC, Sherpa, and ISIS) for spectral analysis of UVIT data. Through these calibration efforts, researchers are able to provide accurate spectral data, thereby supporting scientific research on various astrophysical phenomena.