Machine-Learning Enhanced Diffusion Tensor Imaging with Four Encoding Directions

Joshua Mawuli Ametepe,James Gholam,Leandro Beltrachini,Mara Cercignani,Derek Jones
DOI: https://doi.org/10.1101/2024.08.19.24312228
2024-08-20
Abstract:Purpose: This study aims to reduce Diffusion Tensor MRI (DT-MRI) scan time by minimizing diffusion-weighted measurements. Using machine learning, DT-MRI parameters are accurately estimated with just four tetrahedrally-arranged diffusion-encoded measurements, instead of the usual six or more. This significantly shortens scan duration and is particularly useful in ultra-low field (ULF) MRI studies and for non-compliant populations (e.g., children, the elderly, or those with movement disorders) where long scan times are impractical. Methods: To improve upon a previous tetrahedral encoding approach, this study used a deep learning (DL) model to predict parallel and radial diffusivities and the principal eigenvector of the diffusion tensor with four tetrahedrally-arranged diffusion-weighted measurements. Synthetic data were generated for model training, covering a range of diffusion tensors with uniformly distributed eigenvectors and eigenvalues. Separate DL models were trained to predict diffusivities and principal eigenvectors, then evaluated on a digital phantom and in vivo data collected at 64 mT. Results: The DL models outperformed the previous tetrahedral encoding method in estimating diffusivities, fractional anisotropy, and principal eigenvectors, with significant improvements in ULF experiments, confirming the DL approach's feasibility in low SNR scenarios. However, the models had limitations when the tensor's principal eigenvector aligned with the scanner's axes Conclusion: The study demonstrates the potential of using DL to perform DT-MRI with only four directions in ULF environments, effectively reducing scan durations and addressing numerical instability seen in previous methods. These findings open new possibilities for ULF DT-MRI applications in research and clinical settings, particularly in pediatric neuroimaging
Radiology and Imaging
What problem does this paper attempt to address?
The main problem that this paper attempts to solve is to reduce the scanning time of diffusion - tensor magnetic resonance imaging (DT - MRI) by minimizing the number of diffusion - weighted measurements. Specifically, the researchers use machine - learning techniques to accurately estimate DT - MRI parameters using only four tetrahedrally - arranged diffusion - encoding measurements instead of the six or more usually required. This method can significantly shorten the scanning time and is especially suitable for ultra - low - field (ULF) MRI studies and non - compliant populations (such as children, the elderly, or patients with movement disorders), where long - term scanning is impractical. ### Main Problem Analysis 1. **Reducing Scanning Time**: Traditional DT - MRI requires at least six diffusion - weighted images to accurately estimate the diffusion tensor, which leads to a long scanning time. For certain special populations (such as children, the elderly, or patients with movement disorders), it is very difficult to remain still for a long time. Therefore, reducing the scanning time is an important requirement. 2. **Improving Imaging Quality in Low Signal - to - Noise Ratio Environments**: In low - field and ultra - low - field MRI, due to the low signal - to - noise ratio (SNR), traditional DT - MRI methods face great challenges. The researchers hope that through machine - learning techniques, they can still obtain high - quality DT - MRI images in a low - SNR environment. 3. **Solving the Limitations of the Tetrahedral Encoding Method**: Although the early tetrahedral encoding method can reduce the required number of measurements, numerical instability problems will occur in certain specific situations (such as when the principal eigenvector of the tensor is aligned with the scanner axis). The researchers hope to use machine - learning techniques to overcome these limitations. ### Method Overview To achieve the above goals, the researchers adopted the following methods: 1. **Data Generation**: Generate a training set through synthetic data, which covers the uniformly distributed eigenvalues and eigenvectors of different diffusion tensors. 2. **Machine - Learning Model**: Develop two deep - learning models, one for predicting parallel and radial diffusivities, and the other for predicting the principal eigenvector of the diffusion tensor. These models are trained on synthetic data and validated on digital phantoms and in - vivo data. 3. **Performance Evaluation**: Compare the performance of the four - direction and six - direction encoding methods under different signal - to - noise ratio conditions through Monte Carlo simulations. In addition, compare the performance of the standard tetrahedral encoding method and the machine - learning model in predicting fractional anisotropy (FA) and fiber orientation. ### Results and Conclusions The research results show that the machine - learning model performs better than the standard tetrahedral encoding method under low - SNR conditions and can more accurately estimate the diffusion - tensor parameters. Especially in the low - field MRI environment, the machine - learning method significantly improves the imaging quality and stability. Although there are still errors in certain situations (such as when the principal eigenvector of the tensor is aligned with the scanner axis), these errors have been significantly reduced. In conclusion, this study demonstrates the potential of using machine - learning techniques to perform DT - MRI with four diffusion - encoding directions in an ultra - low - field environment, effectively reducing the scanning time and solving the numerical instability problem of traditional methods in low - SNR conditions. This progress opens up new possibilities for the application of low - field MRI in fields such as pediatric neuroimaging.