Submillimeter diffusion MRI using an in-plane segmented 3D multi-slab acquisition and denoiser-regularized reconstruction

Ziyu Li,Silei Zhu,Karla L. Miller,Wenchuan Wu
DOI: https://doi.org/10.1101/2024.10.10.617536
2024-10-12
Abstract:High-resolution diffusion MRI (dMRI) provides valuable insights into brain microstructure, particularly at submillimeter resolutions, where it enables more precise delineations of curved and crossing white matter pathways. However, achieving high-quality submillimeter dMRI in-vivo poses significant challenges due to the intrinsically low signal-to-noise ratio (SNR), along with the long echo spacing, readout time, and TE required for the large matrix size, leading to significant image distortion, T2* blurring, and T2 signal decay. In this study, we propose a novel acquisition and reconstruction framework to overcome these challenges. Based on numerical simulations, we introduce an in-plane segmented 3D multi-slab acquisition that leverages the optimal SNR efficiency of 3D multi-slab imaging while reducing echo spacing, readout times, and TE using in-plane segmentation. This approach minimizes distortion, improves image sharpness, and enhances SNR. Additionally, we develop a denoiser-regularized reconstruction to suppress noise while maintaining data fidelity, which reconstructs high-SNR images without introducing substantial blurring or bias. Comprehensive in-vivo experiments demonstrate that our method consistently produces high-quality dMRI data at 0.65 mm and 0.53 mm isotropic resolutions on a 3T scanner. The submillimeter dMRI datasets reveal richer microstructural details, reduce gyral bias, and improve U-fiber mapping compared to prospectively acquired 1.22 mm diffusion data. Our method demonstrates robustness at 7T and generates high-SNR 0.61 mm diffusion datasets, showing excellent agreement with previous post-mortem studies at the same scanner. Implemented using the open-source, scanner-agnostic framework Pulseq, our approach may facilitate broader adoption across different scanner platforms to benefit a wider range of applications. These results underscore the potential of our method to advance medical image analysis and neuroscientific research on human brain connectivity.
Neuroscience
What problem does this paper attempt to address?
The problem that this paper attempts to solve is to achieve high - quality sub - millimeter - resolution diffusion magnetic resonance imaging (dMRI) in vivo. Specifically, sub - millimeter dMRI can provide more accurate brain microstructure information, especially in distinguishing curved and crossing white matter pathways. However, achieving high - quality sub - millimeter dMRI faces the following challenges: 1. **Low Signal - to - Noise Ratio (SNR)**: Due to the small voxel size and long echo time (TE), the SNR of sub - millimeter dMRI is usually low. 2. **Image Distortion**: A large matrix size results in a long echo spacing and read - out time, thereby causing significant image distortion. 3. **T2* Blurring**: A long TE will lead to T2* blurring, affecting the effective resolution. 4. **T2 Signal Decay**: A long TE will also lead to T2 signal decay. To overcome these challenges, the authors propose a new acquisition and reconstruction framework, mainly including the following two aspects: 1. **3D Multi - slice Acquisition with Planar Segmentation**: By performing segmentation in - plane, the echo spacing, read - out time and TE are reduced, thereby reducing distortion, improving image sharpness and SNR. 2. **Denoising Regularized Reconstruction**: A denoising regularized reconstruction method has been developed to suppress noise during the reconstruction process while maintaining data consistency and avoiding introducing significant blurring or bias. Through this method, the authors hope to generate high - quality sub - millimeter dMRI data on 3T and 7T scanners and demonstrate its potential in neuroscience research, especially for improving the effect of "gyral bias" and U - fiber tracking.