A Non-Invasive and Non-Contact Jugular Venous Pulse Measurement: A Feasibility Study

Shatabdi Das,Girish Dwivedi,Hadi Afsharan,Omid Kavehei
DOI: https://doi.org/10.1101/2024.06.04.24308313
2024-06-07
Abstract:The Jugular Venous Pulse (JVP) is a vital gauge of proper heart health, reflecting the venous pressure via the Jugular Vein observation. It offers crucial insights for discerning numerous cardiac and pulmonary conditions. Yet, its evaluation is often over- shadowed by the challenges in its process, especially in patients with neck obesity obstructing visibility. Although central venous catheterization provides an alternative, it is invasive and typically reserved for critical cases. Traditional JVP monitoring methods, both visual and via catheterization, present significant hurdles, limiting their frequent application despite their clinical significance. Therefore, there is a pressing need for a non-invasive, efficient JVP monitoring method accessible for home-based and hospitalized patients. Such a method could preempt numerous hospital admissions by offering early indicators. We introduce a non-invasive method using a frequency-modulated continuous wave (FMCW) radar for JVP estimation directly from the skin surface. Our signal processing technique involves an eigen beamforming method to enhance the signal-to-noise ratio for better estimation of JVP. By meticulously fine-tuning various parameters, we identified the optimal settings to enhance the JVP signal quality. In addition, we performed a detailed morphological analysis comparing the JVP and photoplethysmography signals. Our investigation effectively achieved signal localization within a Direction of Arrival (DoA) range from -20◦ to 20◦. This initial study validates the effectiveness of using a 60 GHz far-field radar in measuring JVP.
What problem does this paper attempt to address?
The problem that this paper attempts to solve is to develop a non - invasive jugular venous pulse (JVP) measurement method to overcome the limitations in traditional measurement methods. Traditional JVP monitoring methods, whether through visual observation or central venous catheterization, present significant challenges, especially in patients with obese necks, where these methods are difficult to implement. Although central venous catheterization provides an alternative, it is an invasive method and is usually limited to use in critically ill patients. Therefore, a non - invasive, efficient JVP monitoring method suitable for both home and hospitalized patients is required. This new method can provide early warning and prevent multiple hospitalizations. Specifically, the paper proposes a non - contact JVP measurement method based on frequency - modulated continuous - wave (FMCW) radar technology. This method measures the JVP signal directly from the skin surface and uses signal - processing techniques to improve the signal - to - noise ratio, thereby estimating the JVP more accurately. The research team optimized the signal quality by adjusting various parameters and conducted a detailed morphological analysis, comparing the JVP signal with the photoplethysmography (PPG) signal. In addition, they also verified the effectiveness of signal localization within the direction - of - arrival range of - 20° to 20°, demonstrating the effectiveness of the 60 - GHz far - field radar in measuring JVP. ### Main problem summary: 1. **Limitations of traditional JVP measurement methods**: - **Invasiveness**: Central venous catheterization is an invasive method with the risk of infection and other complications. - **Limited applicability**: Traditional methods are difficult to implement in patients with obese necks. - **High cost**: Professional equipment and technicians are required, limiting its application in homes and general hospitals. 2. **The need for non - invasive JVP measurement**: - **Early warning**: Provide early warning of heart disease and reduce the number of hospitalizations. - **Convenience**: Suitable for home and hospitalized patients, improving the convenience and frequency of monitoring. - **Accuracy**: Ensure the accuracy and reliability of measurement results. 3. **Technical solutions**: - **FMCW radar technology**: Use a 60 - GHz radar sensor to measure JVP non - contact through the skin surface. - **Signal processing**: Adopt the eigen - beamforming method to improve the signal - to - noise ratio and optimize the signal quality. - **Morphological analysis**: Compare the JVP and PPG signals in detail to verify the effectiveness of the measurement method. Through these methods, the paper aims to develop a reliable, non - invasive JVP monitoring system to provide better medical monitoring and support for heart disease patients.