Test-retest repeatability of intravoxel incoherent motion (IVIM) measurements in the cervical cord

Anna Lebret,Simon Lévy,Patrick Freund,Virginie Callot,Maryam Seif
DOI: https://doi.org/10.1101/2024.04.06.24305341
2024-04-07
Abstract:This work aimed at assessing the reliability of intravoxel incoherent motion (IVIM) parameters sensitive to perfusion changes in the cervical cord by determining the test-retest variability across subjects and different post-processing fitting algorithms. IVIM test-retest scans were acquired in the cervical cord (C1-C3) of 10 healthy subjects on a 3T MRI scanner, with a 15-minute break in-between. IVIM parameters, including microvascular volume fraction ( ), pseudo-diffusion coefficient ( ), blood flow-related coefficient ( · ), and diffusion coefficient ( ), were derived using voxel-wise and region of interest (ROI)-wise fits. The reliability of each IVIM parameter was determined with coefficients of variation (CV), intraclass correlation coefficients (ICC), Bland-Altman analysis and linear regression. To assess the effects of the different fitting approaches, a two-way repeated-measures analysis of variance (ANOVA) was conducted on the CVs calculated across fitting algorithms. Mean CVs of IVIM parameters calculated across subjects using the voxel-wise fit was lower in the white matter (WM) and grey matter (GM) (2.6% to 15.6%; 2.2% to 16.4%, respectively) compared with those calculated using the ROI-wise fit approach (WM: 4.5%-32.2%; GM: 3.4%-53.4%). The voxel-wise fit in the WM yielded higher ICC values (good-to-excellent, 0.71 – 0.97) compared to the ROI-wise fit approach (0.49 – 0.90). IVIM parameters, derived using the voxel-wise fitting approach, demonstrated a high reliability in the cervical cord. Robust IVIM metrics, observed across scans and subjects, can facilitate studies targeting perfusion impairment and pave the way to future clinical trials assessing perfusion impairment as a potential quantitative biomarker.
Radiology and Imaging
What problem does this paper attempt to address?
This paper aims to evaluate the test - retest reliability in the measurement of intravoxel incoherent motion (IVIM) parameters in the cervical spine, especially the sensitivity of these parameters to microcirculation changes in the cervical spine region. The study achieved this goal by determining the test - retest variability under different post - processing fitting algorithms. Specifically, the researchers conducted IVIM test - retest scans on the cervical spines (C1 - C3 levels) of 10 healthy subjects with a 15 - minute interval between each scan. Using voxel - level and region - of - interest (ROI) - level fitting methods, IVIM parameters including microvascular volume fraction (\(F\)), pseudo - diffusion coefficient (\(D^*\)), blood - flow - related coefficient (\(F\cdot D^*\)) and diffusion coefficient (\(D\)) were derived from the IVIM data. To evaluate the influence of different fitting methods, the researchers conducted a two - factor repeated - measures analysis of variance (ANOVA) and analyzed the coefficient of variation (CV) calculated by different fitting algorithms. The results showed that the average CV of IVIM parameters calculated using the voxel - level fitting method in white matter and gray matter was lower (white matter: 2.6% to 15.6%; gray matter: 2.2% to 16.4%), while the CV calculated using the ROI - level fitting method was higher (white matter: 4.5% to 32.2%; gray matter: 3.4% to 53.4%). In addition, the intra - class correlation coefficient (ICC) value of the voxel - level fitting method in white matter was higher (good to excellent, 0.71 – 0.97), while the ICC value range of the ROI - level fitting method was 0.49 – 0.90. Overall, the study found that the IVIM parameters obtained using the voxel - level fitting method showed high reliability in the cervical spine region, which is helpful for future research on perfusion disorders and may provide quantitative biomarkers for future clinical trials.