Quantitative perfusion and water transport time model from multi b-value diffusion magnetic resonance imaging validated against neutron capture microspheres
M. Liu,N. Saadat,Y. Jeong,S. Roth,M. Niekrasz,M. Giurcanu,T. Carroll,G. Christoforidis
2023-04-04
Abstract:Intravoxel Incoherent Motion (IVIM) is a non-contrast magnetic resonance imaging diffusion-based scan that uses a multitude of b-values to measure various speeds of molecular perfusion and diffusion, sidestepping inaccuracy of arterial input functions or bolus kinetics in quantitative imaging. We test a new method of IVIM quantification and compare our values to reference standard neutron capture microspheres across normocapnia, CO2 induced hypercapnia, and middle cerebral artery occlusion in a controlled animal model. Perfusion quantification in ml/100g/min compared to microsphere perfusion uses the 3D gaussian probability distribution and defined water transport time as when 50% of the molecules remain in the tissue of interest. Perfusion, water transport time, and infarct volume was compared to reference standards. Simulations were studied to suppress non-specific cerebrospinal fluid (CSF). Linear regression analysis of quantitative perfusion returned correlation (slope = .55, intercept = 52.5, $R^2$= .64). Linear regression for water transport time asymmetry in infarcted tissue was excellent (slope = .59, intercept = .3, $R^2$ = .93). Strong linear agreement also was found for infarct volume (slope = 1.01, $R^2$= .79). Simulation of CSF suppression via inversion recovery returned blood signal reduced by 82% from combined T1 and T2 effects. Intra-physiologic state comparison of perfusion shows potential partial volume effects which require further study especially in disease states. The accuracy and sensitivity of IVIM provides evidence that observed signal changes reflect cytotoxic edema and tissue perfusion. Partial volume contamination of CSF may be better removed during post-processing rather than with inversion recovery to avoid artificial loss of blood signal.
Medical Physics,Image and Video Processing
What problem does this paper attempt to address?
The problems that this paper attempts to solve are: How to quantitatively measure the perfusion and water transport time of brain tissue through multi - b - value diffusion MRI (multi b - value diffusion MRI) and verify its accuracy. Specifically, the author aims to evaluate a new IVIM (Intravoxel Incoherent Motion) quantification method to determine whether it can provide accurate and quantifiable cerebral blood flow (qCBF) measurement results and compare it with standard reference methods (such as the neutron - capture microsphere method).
### Main problems include:
1. **Quantitative measurement of perfusion**:
- Can IVIM provide accurate quantitative perfusion measurements under different physiological states (such as normal carbon dioxide levels, high carbon dioxide levels, and ischemic stroke)?
- Is it feasible to use "water transport time" (WTT) to quantify perfusion, and can it match the traditional dynamic susceptibility - contrast (DSC) mean transit time (MTT)?
2. **Verification of accuracy**:
- Are the perfusion values measured by IVIM consistent with the standard perfusion values measured by the neutron - capture microsphere method?
- Are the infarct volumes measured by IVIM consistent with the infarct volumes measured by diffusion tensor imaging (DTI)?
3. **Confirmation of signal sources**:
- Confirm whether the IVIM signal changes truly reflect cytotoxic edema and tissue perfusion, rather than artifacts caused by other factors (such as cerebrospinal fluid flow).
4. **Impact of partial volume effect**:
- Evaluate the possible partial volume effect in IVIM images, especially the contamination of the perfusion signal by CSF, and explore how to better remove these effects in post - processing.
### Formula summary:
- **IVIM biexponential model**:
\[
S(b)=S(0)\left[f e^{-b D^{*}}+(1 - f)e^{-b D}\right]
\]
where \(D^{*}\) is the pseudo - diffusion coefficient, \(f\) is the blood volume fraction (CBV), and \(D\) is the diffusion coefficient.
- **Definition of water transport time (WTT)**:
\[
\int_{0}^{\infty}\frac{1}{\sqrt{4\pi D^{*}t}}e^{-\frac{r^{2}}{4D^{*}t}}dr = 0.5
\]
- **Calculation of quantitative cerebral blood flow (qCBF)**:
\[
qCBF\left[\text{ml/100g/min}\right]=\frac{f\times f_{0}}{\rho\cdot2\sqrt{\pi D^{*}}}\approx f\cdot D^{*}\times93,000
\]
where \(\rho = 1.04\text{g/mL}\), \(f_{0}=0.79\).
Through the solution of these problems, the research aims to prove that IVIM, as a non - invasive, contrast - agent - free MRI technique, has potential application value in clinical and research, especially in cases where long - term or multi - center studies are required.