Noise adaptive beamforming for linear array photoacoustic imaging

Souradip Paul,Subhamoy Mandal,Mayanglambam Suheshkumar Singh
DOI: https://doi.org/10.48550/arXiv.2011.08414
2021-07-28
Abstract:Delay-and-sum (DAS) algorithms are widely used for beamforming in linear array photoacoustic imaging systems and are characterized by fast execution. However, these algorithms suffer from various drawbacks like low resolution, low contrast, high sidelobe artifacts and lack of visual coherence. More recently, adaptive weighting was introduced to improve the reconstruction image quality. Unfortunately, the existing state-of-the-art adaptive beamforming algorithms are computationally expensive and do not consider the specific noise characteristics of the acquired ultrasonic signal. In this article, we present a new adaptive weighting factor named the variational coherence factor (VCF), which takes into account the noise level variations of radio-frequency data. The proposed technique provides superior results in terms of image resolution, sidelobe reduction, signal-to-noise and contrast level improvement. The quantitative results of the numerical simulations and phantom imaging show that the proposed VCF assisted DAS method leads to 55% and 25% improvement in FWHM, 57% and 32% improvement in SNR, respectively, compared to the state-of-the-art DAS-based methods. The results demonstrate that the proposed method can effectively improve the reconstructed image quality and deliver satisfactory imaging performance even with a limited number of sensor elements. The proposed method can potentially reduce the instrumentation cost of the photoacoustic imaging system and contribute toward the clinical translation of the modality.
Medical Physics,Image and Video Processing
What problem does this paper attempt to address?
The main problem that this paper attempts to solve is the defects existing in the Delay - and - Sum (DAS) algorithm in the existing linear - array photoacoustic imaging systems, such as low resolution, low contrast, high sidelobe artifacts and lack of visual coherence. Although adaptive weighting methods have been introduced to improve the quality of reconstructed images, these advanced adaptive beamforming algorithms are computationally very expensive and do not take into account the specific noise characteristics of the acquired ultrasonic signals. To solve these problems, the author proposes a new adaptive weighting factor - the Variational Coherence Factor (VCF), which takes into account the variation in the noise level of the radio - frequency data. Compared with the existing DAS - based methods, the VCF - assisted DAS method improves by 55% and 25% respectively in terms of Full Width at Half Maximum (FWHM) and Signal - to - Noise Ratio (SNR), as well as a 32% SNR improvement. In addition, this method can provide satisfactory imaging performance even when the number of sensor elements is limited, which helps to reduce the instrument cost of the photoacoustic imaging system and promote its clinical application. The quantitative results of numerical simulations and phantom imaging show that the proposed VCF - assisted DAS method can effectively improve the quality of reconstructed images, especially showing stronger robustness when dealing with data of different noise levels. This makes the technology not only suitable for real - time image reconstruction, but also able to maintain good image quality when the number of sensor elements is limited, thereby potentially reducing the cost of photoacoustic imaging systems and enabling them to be widely used in countries with weaker economies and limited clinical infrastructure.