Portable magnetometry for detection of biomagnetism in ambient environments

M. E. Limes,E. L. Foley,T. W. Kornack,S. Caliga,S. McBride,A. Braun,W. Lee,V. G. Lucivero,M. V. Romalis
DOI: https://doi.org/10.1103/PhysRevApplied.14.011002
2020-06-01
Abstract:We present a method of optical magnetometry with parts-per-billion resolution that is able to detect biomagnetic signals generated from the human brain and heart in Earth's ambient environment. Our magnetically silent sensors measure the total magnetic field by detecting the free-precession frequency of highly spin-polarized alkali metal vapor. A first-order gradiometer is formed from two magnetometers that are separated by a 3 cm baseline. Our gradiometer operates from a laptop consuming 5 W over a USB port, enabled by state-of-the-art micro-fabricated alkali vapor cells, advanced thermal insulation, custom electronics, and laser packages within the sensor head. The gradiometer obtains a sensitivity of 16 fT/cm/Hz$^{1/2}$ outdoors, which we use to detect neuronal electrical currents and magnetic cardiography signals. Recording of neuronal magnetic fields is one of a few available methods for non-invasive functional brain imaging that usually requires extensive magnetic shielding and other infractructure. This work demonstrates the possibility of a dense array of portable biomagnetic sensors that are deployable in a variety of natural environments.
Medical Physics,Atomic Physics,Instrumentation and Detectors
What problem does this paper attempt to address?
This paper aims to solve the technical problems in detecting biomagnetic signals in the natural environment. Specifically, the authors have developed a portable optical gradiometer that can directly detect the weak biomagnetic field signals generated by the human brain and heart in the natural environment of the earth's magnetic field without the need for additional magnetic shielding devices. This method can detect neuronal current and magnetocardiogram signals with extremely high sensitivity (reaching 16 femtotesla per square root of hertz per centimeter), thus providing a new possibility for non - invasive functional brain imaging. Although traditional magnetoencephalography (MEG) and electroencephalography (EEG) techniques can provide neural current source imaging with millisecond - level resolution, they usually require complex magnetic shielding facilities and other infrastructures, which limit their application scope. The portable sensor introduced in this paper not only overcomes these limitations but also can be deployed in a variety of natural environments, providing a broader application prospect for future biomagnetic research. For example, this technology can be used for real - time monitoring of cardiac activity and can even achieve rapid, non - contact cardiac diagnosis in noisy environments such as laboratories or hospitals. In conclusion, the main contribution of this paper lies in proposing an innovative portable optical gradient measurement method, which can achieve high - sensitivity biomagnetic signal detection in the natural environment and open up new paths for biomedical research and clinical applications.