Front-end-Electronics for the SiPM-readout gaseous TPC for neutrinoless double beta decay search

K. Z. Nakamura,S. Ban,A. K. Ichikawa,M. Ikeno,K. D. Nakamura,T. Nakaya,S. Obara,S. Tanaka,T. Uchida,M. Yoshida
DOI: https://doi.org/10.1109/TNS.2020.2988716
2020-01-06
Abstract:We have developed a dedicated front-end-electronics board for a high-pressure xenon gas time projection chamber for a neutrinoless double-beta decay search. The ionization signal is readout by detecting electroluminescence photons with SiPM's. The board readout the signal from 56~SiPM's through the DC-coupling and record the waveforms at 5 MS/s with a wide dynamic range up to 7,000 photons/200 ns. The SiPM bias voltages are provided by the board and can be adjusted for each SiPM. In order to calibrate and monitor the SiPM gain, additional auxiliary ADC measures 1 photon-equivalent dark current. The obtained performance satisfies the requirement for a neutrinoless double-beta decay search.
Instrumentation and Detectors,High Energy Physics - Experiment,Nuclear Experiment
What problem does this paper attempt to address?
The problem that this paper attempts to solve is to develop a specialized front - end electronic board (AxFEB) for the detection of neutrinoless double - beta decay (0νββ) in a high - pressure xenon time - projection chamber (TPC). Specifically, this research aims to meet the following requirements: 1. **Dynamic range**: It needs to be able to handle signal intensity changes from 4 to 7000 photons/200 nanoseconds. 2. **Recording length**: It needs to be able to record signals for 150 microseconds. 3. **Single - photoelectron signal measurement**: For calibration, it needs to be able to measure the dark current equivalent to a single - photoelectron. 4. **Independent bias voltage supply**: Each SiPM (Silicon Photomultiplier) requires independent bias voltage regulation with an accuracy up to the millivolt level. 5. **Low cost and good scalability**: The design needs to be suitable for expansion to thousands of channels and be low - cost. To achieve these goals, the researchers designed the AxFEB. This board can read the signals of 56 SiPMs, record waveforms through DC - coupling, and has a wide dynamic range. In addition, the AxFEB also includes an auxiliary ADC for measuring the dark current equivalent to a single - photoelectron to calibrate and monitor the gain of SiPMs. These design features enable the AxFEB to meet the requirements of neutrinoless double - beta decay search experiments.