Numerical study of the influence of two-phase flow with different inlet velocities on the angular stability of double crystal monochromator

Sasa Gao,Hongzhe Zhai,Wenjie Zhang,Yuan Song,Jie Yang,Xuepeng Gong,Qipeng Lu
DOI: https://doi.org/10.1016/j.nima.2024.169144
2024-05-01
Abstract:In order to solve the problem of double crystal monochromator (DCM) vibration caused by the liquid nitrogen (LN2) circulation system in Shanghai Synchronous Radiation Facility (SSRF), the flow-induced vibration of single-axis and four-axis flexure hinges DCM is studied using the unidirectional fluid-solid coupling method. This research mainly investigated the influence of the different inlet velocities on the distribution of the two-phase, pressure, and velocity flow in the cooling pipeline, as well as the overall deformation of DCM structure and the crystal vibration. The results show that the inlet velocity has little effect on the distribution and flow pattern of the two-phase flow, while the dynamic pressure and total pressure in the pipeline increase with the increasement of the inlet flow velocity, and the vortex will disappear as the velocity increases. Numerical simulations show that the four-axis flexure hinge DCM is more stable than the single-axis flexure hinge DCM. When the inlet velocity is 1.0 m/s, the angle stability is the best. After removing the DC component, the vibration frequency of the single-axis flexible hinge DCM is 84 Hz, and the vibration frequency of the four-axis flexible hinge DCM is 96 Hz.
physics, particles & fields, nuclear,nuclear science & technology,instruments & instrumentation
What problem does this paper attempt to address?