First test results of the HGCAL concentrator ASICs: ECON-T and ECON-D
Davide Braga,Grace Cummings,Cristinel Gingu,James Hirschauer,James Hoff,Pamela Klabbers,Neha Kharwadkar,Cristina Mantilla-Suarez,Daniel Noonan,Paul Rubinov,Alpana Shenai,Chinar Syal,Xiaoran Wang,Ralph Wickwire,Gianmario Bergamin,Davide Ceresa,Szymon Kulis,Matteo Lupi,Simone Scarfì,Duje Coko,Mike Hammer,Jon Wilson,Bhim Bam,Jyoti Babbar,Alex Campbell,Yulun Miao,Bram Feas,Datao Gong,Di Guo,Dongxu Yang,Jeffrey Prinzie,Jingbo Ye,Paul Jozef Leroux,Paulo Moreira,Pedro Leitao,Rui De Oliveira,the CMS collaboration
DOI: https://doi.org/10.1088/1748-0221/19/03/c03050
2024-03-23
Journal of Instrumentation
Abstract:With over 6 million channels, the High Granularity Calorimeter for the CMS HL-LHC upgrade presents a unique data transmission challenge. The ECON ASICs provide a critical stage of on-detector data compression and selection for the trigger path (ECON-T) and data acquisition path (ECON-D) of the HGCAL. The ASICs, fabricated in 65 nm CMOS, are radiation tolerant up to 200 Mrad and require low power consumption: < 2.5 mW/sensor-channel per chip. We report on the first functionality and radiation tests for the ECON-D-P1 full-functionality prototype. We present a comparison of single event effect (SEE) cross sections measured for different methods of triple modular redundancy using test results from the ECON-T-P1 full-functionality prototype.
instruments & instrumentation