Single-atom electron paramagnetic resonance in a scanning tunneling microscope driven by a radiofrequency antenna at 4 K

T. S. Seifert,S. Kovarik,C. Nistor,L. Persichetti,S. Stepanow,P. Gambardella
DOI: https://doi.org/10.1103/PhysRevResearch.2.013032
2019-11-25
Abstract:Combining electron paramagnetic resonance (EPR) with scanning tunneling microscopy (STM) enables detailed insight into the interactions and magnetic properties of single atoms on surfaces. A requirement for EPR-STM is the efficient coupling of microwave excitations to the tunnel junction. Here, we achieve a coupling efficiency of the order of unity by using a radiofrequency antenna placed parallel to the STM tip, which we interpret using a simple capacitive-coupling model. We further demonstrate the possibility to perform EPR-STM routinely above 4 K using amplitude as well as frequency modulation of the radiofrequency excitation. We directly compare different acquisition modes on hydrogenated Ti atoms and highlight the advantages of frequency and magnetic field sweeps as well as amplitude and frequency modulation in order to maximize the EPR signal. The possibility to tune the microwave-excitation scheme and to perform EPR-STM at relatively high temperature and high power opens this technique to a broad range of experiments, ranging from pulsed EPR spectroscopy to coherent spin manipulation of single atom ensembles.
Mesoscale and Nanoscale Physics,Materials Science
What problem does this paper attempt to address?
The main problem that this paper attempts to solve is to increase the signal strength and signal - to - noise ratio of electron paramagnetic resonance scanning tunneling microscopy (EPR - STM) technology at relatively high temperatures (above 4 K), so that it can be applied to a wider range of experiments. Specifically, the author achieves this goal by introducing a new type of radio - frequency (RF) antenna indirect coupling scheme. ### Main Problems 1. **Increase the Signal Strength and Signal - to - Noise Ratio of EPR - STM**: - Traditional EPR - STM experiments are usually carried out at extremely low temperatures (<1.2 K) to reduce thermal noise and improve energy resolution. However, this limits the scope of its experimental applications. - The author hopes to achieve efficient EPR - STM operation at higher temperatures (such as 4 K and above) and maintain a high signal - to - noise ratio. 2. **Optimize RF Coupling Efficiency**: - In order to enhance the EPR signal, it is necessary to optimize the coupling efficiency of RF voltage to the tunneling junction. The traditional method directly feeds the RF voltage into the tunneling junction through the STM probe, but this method has problems such as low transmission efficiency and poor signal - to - noise ratio. - The author proposes a new indirect coupling scheme, that is, using an RF antenna placed near the STM probe to couple the RF voltage, thereby significantly improving the coupling efficiency. 3. **Compare Different EPR Detection Modes**: - The author compares the effects of different EPR detection modes such as frequency sweep, magnetic field sweep, amplitude modulation, and frequency modulation to determine which mode can maximize the EPR signal. ### Solutions 1. **Indirect RF Coupling Scheme**: - Use an RF antenna placed near the STM probe to transfer the RF voltage to the tunneling junction through capacitive coupling. This scheme enables the RF voltage to reach a higher amplitude at the tunneling junction, thereby enhancing the EPR signal. - The experimental results show that this scheme can achieve a coupling efficiency close to 1 in the frequency range below 40 GHz, which is much higher than the traditional method. 2. **Optimize EPR Detection Mode**: - The author finds that using magnetic field sweep can significantly reduce the acquisition time of the EPR spectrum, and compared with frequency sweep, the magnetic moment results obtained by the two are consistent. - In addition, the author also explores the influence of amplitude modulation and frequency modulation on the signal - to - noise ratio, and points out that choosing an appropriate modulation method can further improve the signal - to - noise ratio. ### Conclusions By introducing the indirect RF coupling scheme and optimizing the EPR detection mode, the author has successfully achieved efficient EPR - STM operation at temperatures above 4 K, and demonstrated its high resolution and high sensitivity on the single - atom scale. This progress provides new tools and technical support for future quantum computing experiments and other single - atom studies. ### Formula Summary - **Rabi Rate**: \[ \Omega=\frac{g \mu_B B_A}{2\hbar} \] - \( g \) is the g - factor, \( \mu_B \) is the Bohr magneton, \( B_A \) is the magnetic field generated by the RF antenna, and \( \hbar \) is the reduced Planck constant. - **Maximum Tunneling Current Variation**: \[ \Delta I_{DC} \approx I_{DC} a_M\left(\frac{\Omega T_s}{1 + (\Omega T_s)^2}\right) \] - \( I_{DC} \) is the direct - current tunneling current, \( a_M \) is the tunneling magnetoresistance efficiency, and \( T_s \) is the spin lifetime. - **EPR Signal Amplitude**: \[ A(\omega) \propto \tanh\left(\frac{\hbar \omega}{2 k_B T}\right) \] - \( \omega \) is the angular frequency, \( k_B \) is the Boltzmann constant, and \( T \) is the temperature. These formulas help to explain.