Charge collection properties of irradiated depleted CMOS pixel test structures

I. Mandić,V. Cindro,A. Gorišek,B. Hiti,G. Kramberger,M. Zavrtanik,M. Mikuž,T. Hemperek
DOI: https://doi.org/10.1016/j.nima.2018.06.062
2018-01-23
Abstract:Edge-TCT and charge collection measurements with passive test structures made in LFoundry 150 nm CMOS process on p-type substrate with initial resistivity of over 3 k$\Omega$cm are presented. Measurements were made before and after irradiation with reactor neutrons up to 2$\cdot$10$^{15}$ n$_{\mathrm{eq}}$/cm$^2$. Two sets of devices were investigated: unthinned (700 $\mu$m) with substrate biased through the implant on top and thinned (200 $\mu$m) with processed and metallised back plane. Depleted depth was estimated with Edge-TCT and collected charge was measured with $^{90}$Sr source using an external amplifier with 25 ns shaping time. Depleted depth at given bias voltage decreased with increasing neutron fluence but it was still larger than 70 $\mu$m at 250 V after the highest fluence. After irradiation much higher collected charge was measured with thinned detectors with processed back plane although the same depleted depth was observed with Edge-TCT. Most probable value of collected charge of over 5000 electrons was measured also after irradiation to 2$\cdot$10$^{15}$ n$_{\mathrm{eq}}$/cm$^2$. This is sufficient to ensure successful operation of these detectors at the outer layer of the pixel detector in the ATLAS experiment at the upgraded HL-LHC.