Abstract:System compliances of two testing machines (Keysight T150 and Instron 3365) were studied for the tensile testing of carbon nanotube (CNT) fibers. Due to the different gripping methods, the T150's system compliance was nearly zero, while that of the Instron was nonnegligible. By analyzing the data dispersion with the Weibull theory, a safe gauge length of >10 mm was suggested for CNT fibers. Therefore, a standard test procedure should involve the compliance evaluation, choice of gauge length, and Weibull statistical analysis.
What problem does this paper attempt to address?
This paper attempts to solve the problem of inaccurate measurement of carbon nanotube fibers (CNT fibers) in tensile tests due to different system compliance and fixture methods. Specifically, the research aims to:
1. **Evaluate the system compliance of different testing machines**: By comparing the system compliance of two different testing machines, Keysight T150 and Instron 3365, the study found that due to different fixture methods, the system compliance of T150 is almost zero, while the system compliance of Instron cannot be ignored.
2. **Determine the appropriate gauge length**: Through the analysis of data discreteness and combined with Weibull theory, a safe gauge length (> 10 mm) is recommended to ensure the accuracy of measurement results.
3. **Propose a standardized testing procedure**: In order to accurately measure the mechanical properties of CNT fibers (such as modulus, strength, fracture strain, etc.), the study proposes a standard testing procedure including system compliance evaluation, selection of appropriate gauge length, and Weibull statistical analysis.
### Key problems and solutions
- **Influence of system compliance**:
- System compliance refers to the deformation of the testing equipment itself when force is applied, which will affect the measured fiber modulus. In this paper, the total compliance \(C_{\text{tot}}\) is described as the sum of the system compliance \(C_{\text{sys}}\) and the sample compliance \(C_f\) by the formula \(C_{\text{tot}} = C_{\text{sys}} + C_f\).
- **Influence of fixture methods**:
- Different fixture methods will lead to different system compliance. For example, the pneumatic grip may produce large deformation when clamping cardboard, resulting in large system compliance; while the split - shim grip can hold the sample more firmly and has smaller system compliance.
- **Selection of gauge length**:
- A shorter gauge length can easily avoid structural defects in the fiber, but may lead to overly high strength or modulus measurement values. A longer gauge length can reduce data discreteness, but the influence of system compliance needs to be considered. Through Weibull statistical analysis, the study recommends using a gauge length greater than 10 mm.
### Summary
This paper provides a set of standardized testing procedures through system compliance evaluation, gauge length selection, and Weibull statistical analysis to ensure accurate measurement of the mechanical properties of CNT fibers. This is of great significance for formulating new testing standards applicable to CNT fibers.