Clock Distributing for BaF2 Readout Electronics at CSNS-WNS

Bing He,Ping Cao,De-Liang-Zhang,Qi Wang,Ya-Xi Zhang,Xin-Cheng Qi,Qi-An
DOI: https://doi.org/10.48550/arXiv.1602.06635
2016-02-22
Abstract:aF2 (Barium Fluoride) detector array is designed for the measurement of (n,{\gamma}) cross section precisely at CSNS-WNS (white neutron source at China Spallation Neutron Source). It is a 4{\pi}solid angle-shaped detector array consisting of 92 BaF2 crystal elements. To discriminate signals from BaF2 detector, pulse shape discrimination methodology is used, which is supported by waveform digitization technique. There are total 92 channels for digitizing. The precision and synchronization of clock distribution restricts the performance of waveform digitizing. In this paper, the clock prototype for BaF2 readout electronics at CSNS-WNS is introduced. It is based on PXIe platform and has a twin-stage tree topology. In the first stage, clock is distributed from the tree root to each PXIe crate synchronously through coaxial cable over long distance, while in the second stage, clock is further distributed to each electronic module through PXIe dedicated differential star bus. With the help of this topology, each tree node can fan out up to 20 clocks with 3U size. Test result shows the clock jitter is less than 20ps, which can meet the requirement of BaF2 readout electronics. Besides, this clock system has advantages of high density, simplicity, scalability and cost saving, which makes it can be used in other applications of clock distributing preciously.
Instrumentation and Detectors
What problem does this paper attempt to address?