Mode Error Analysis of Impedance Measurement using Twin Wires

Huang Liang-Sheng,Yoshiro Irie,Liu Yu-Dong,Wang Sheng
DOI: https://doi.org/10.48550/arXiv.1410.3201
2014-10-13
Abstract:Both longitudinal and transverse coupling impedance for some critical components need to be measured for accelerator design. The twin wires method is widely used to measure longitudinal and transverse impedance on the bench. A mode error is induced when the twin wires method is used with a two-port network analyzer. Here, the mode error is analyzed theoretically and an example analysis is given. Moreover, the mode error in the measurement is a few percent when a hybrid with no less than 25 dB isolation and a splitter with no less than 20 dB magnitude error are used.
Accelerator Physics
What problem does this paper attempt to address?
### Problems the Paper Attempts to Solve This paper aims to analyze the mode errors that arise when using the two-wire method to measure the longitudinal and transverse coupling impedance of key accelerator components. Specifically: 1. **Background and Importance**: - Coupling impedance is an important parameter that describes the electromagnetic interaction between a charged particle beam and the surrounding environment of the accelerator. - Measuring coupling impedance is crucial for accelerator design because improper coupling impedance can lead to component overheating and limit the increase in beam power. 2. **Application of the Two-Wire Method**: - The two-wire method is a widely used technique for measuring longitudinal and transverse impedance. - In a laboratory environment, the two-wire method measures transverse coupling impedance by inserting two parallel wires into the device under test (DUT) to generate a dipole current moment. - Recently, the two-wire method has also been applied to measure longitudinal coupling impedance using in-phase currents (common-mode signals). 3. **Sources of Mode Errors**: - Mode errors occur when using a two-port network analyzer for impedance measurements. - Mode errors are primarily determined by the quality of mode generators, such as mixers and splitters. - Using low-quality mode generators can lead to significant mode errors, affecting the accuracy of measurement results. 4. **Research Objectives**: - Theoretically analyze the mechanisms of mode error generation. - Provide a specific example to demonstrate the impact of mode errors in actual measurements. - Offer suggestions to reduce mode errors, such as using mixers with isolation not less than 25 dB and splitters with amplitude errors not exceeding 20 dB. ### Summary Through theoretical analysis and experimental verification, the paper explores the issue of mode errors in measuring coupling impedance using the two-wire method and proposes some recommendations to improve measurement accuracy. This is of great significance for ensuring the reliability and performance of accelerator design.