Velocity map imaging of a slow beam of ammonia molecules inside a quadrupole guide

Marina Quintero Pérez,Paul Jansen,Hendrick L. Bethlem
DOI: https://doi.org/10.1039/C2CP40822H
2012-03-15
Abstract:Velocity map imaging inside an electrostatic quadrupole guide is demonstrated. By switching the voltages that are applied to the rods, the quadrupole can be used for guiding Stark decelerated molecules and for extracting the ions. The extraction field is homogeneous along the axis of the quadrupole while it defocuses the ions in the direction perpendicular to both the axis of the quadrupole and the axis of the ion optics. To compensate for this astigmatism, a series of planar electrodes with horizontal and vertical slits is used. A velocity resolution of 35 m/s is obtained. It is shown that signal due to thermal background can be eliminated, resulting in the detection of slow molecules with an increased signal-to-noise ratio. As an illustration of the resolving power, we have used the velocity map imaging system to characterize the phase-space distribution of a Stark decelerated ammonia beam.
Chemical Physics,Atomic Physics,Instrumentation and Detectors
What problem does this paper attempt to address?
This paper aims to address the issue of how to achieve Velocity Map Imaging (VMI) in an electrostatic quadrupole guide. Specifically, the researchers aim to achieve high-resolution velocity measurements of slow molecular beams by optimizing the voltage settings in the electrostatic quadrupole guide, effectively distinguishing background thermal molecular signals, and thereby improving the signal-to-noise ratio. ### Main Issues 1. **Improving Velocity Resolution**: By improving the ion optics system in the electrostatic quadrupole guide, achieve velocity measurements of slow molecules with a resolution of 35 m/s. 2. **Eliminating Background Signals**: Effectively eliminate the signals of background thermal molecules through VMI technology, thereby improving the signal-to-noise ratio of detected slow molecules. 3. **Optimizing Experimental Configuration**: Design and validate a new configuration of the electrostatic quadrupole guide and ion optics system to achieve the above goals. ### Solutions - **Electrostatic Quadrupole Guide**: By switching the voltage applied to the quadrupole, the quadrupole can both guide the Stark-decelerated molecules and extract ions. - **Compensating Astigmatism**: Use a series of planar electrodes with horizontal and vertical slits to compensate for astigmatism caused by the quadrupole. - **Multiphoton Ionization**: Use Resonance-Enhanced Multiphoton Ionization (REMPI) technology to ionize and detect molecules. - **Optimizing Voltage Settings**: Through experiments and simulations, determine the optimal voltage settings so that ions with the same initial velocity but different initial positions can focus on the same position on the detector. ### Experimental Results - **Velocity Resolution**: Achieved a velocity resolution of 35 m/s. - **Background Signal Elimination**: Successfully eliminated the signals of background thermal molecules, improving the signal-to-noise ratio of slow molecules. - **Molecular Beam Characterization**: Successfully characterized the phase space distribution of the Stark-decelerated ammonia molecular beam through the VMI system. ### Conclusion This study demonstrates the feasibility of achieving Velocity Map Imaging in an electrostatic quadrupole guide, achieving sufficient resolution for research in fields such as electrostatic traps, storage rings, and molecular fountains. Through VMI technology, researchers can detect slow molecules without interference from background thermal molecular signals.